mscFrDteDynDlciDefsCommittedInformationRate

Module: Nortel-MsCarrier-MscPassport-FrameRelayDteMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-FrameRelayDteMIB::mscFrDteDynDlciDefsCommittedInformationRate

OID (numeric): 1.3.6.1.4.1.562.36.2.1.101.5.10.1.3

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: The average number of bits to be transferred per second over the DLCI to the DCE. When this attribute is set to zero, the link speed will be used instead.

What is mscFrDteDynDlciDefsCommittedInformationRate?

This read-write value (0-48,000,000 bits/sec, default 64000) sets the Committed Information Rate -- the average throughput contracted for the dynamic-DLCI default provisioning profile (DynDlciDefs) across the DLCI to the DCE; leaving it at 0 tells the Passport to use the physical link speed instead. An admin sets this to match the bandwidth actually purchased from the carrier for this virtual circuit, since it is the baseline mscFrDteRateEnforcement measures bursts against.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.101.5.10.1.3
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-FrameRelayDteMIB::mscFrDteDynDlciDefsCommittedInformationRate

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.101.5.10.1.3.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-FrameRelayDteMIB::mscFrDteDynDlciDefsCommittedInformationRate.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.101.5.10.1.3.1 i <value>

Start monitoring Nortel MscPassport multiservice switch (Frame Relay DTE/DLCI) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-FrameRelayDteMIB::mscFrDteDynDlciDefsCommittedInformationRate OID value, configure state conditions and alerts, and monitor any Nortel MscPassport multiservice switch (Frame Relay DTE/DLCI) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.101mscFrDteNortel-MsCarrier-MscPassport-FrameRelayDteMIB
1.3.6.1.4.1.562.36.2.1.101.5mscFrDteDynDlciDefsNortel-MsCarrier-MscPassport-FrameRelayDteMIB
1.3.6.1.4.1.562.36.2.1.101.5.10mscFrDteDynDlciDefsProvTableNortel-MsCarrier-MscPassport-FrameRelayDteMIB
1.3.6.1.4.1.562.36.2.1.101.5.10.1mscFrDteDynDlciDefsProvEntryNortel-MsCarrier-MscPassport-FrameRelayDteMIB
1.3.6.1.4.1.562.36.2.1.101.5.10.1.3mscFrDteDynDlciDefsCommittedInformationRateNortel-MsCarrier-MscPassport-FrameRelayDteMIB