All MIBs › Nortel-MsCarrier-MscPassport-FrameRelayDteMIB › mscFrDteDlciReceivedOctets
mscFrDteDlciReceivedOctets
Module: Nortel-MsCarrier-MscPassport-FrameRelayDteMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-FrameRelayDteMIB::mscFrDteDlciReceivedOctets
OID (numeric): 1.3.6.1.4.1.562.36.2.1.101.8.11.1.10
Node type: OBJECT-TYPE
Type: Counter32
Access: read-only
Description: The number of octets sent from this virtual circuit since it was created. This counter will wrap around to 0 when it exceeds its maximum count.
What is mscFrDteDlciReceivedOctets?
This read-only Counter32 counts octets received across this DLCI (virtual circuit) since it was created. An admin combines this with the matching frame counter to compute average frame size, and watches its growth rate for capacity planning; it wraps to 0 once it exceeds its maximum count.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.101.8.11.1.10 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-FrameRelayDteMIB::mscFrDteDlciReceivedOctets
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.101.8.11.1.10.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-FrameRelayDteMIB::mscFrDteDlciReceivedOctets.1
Start monitoring Nortel MscPassport multiservice switch (Frame Relay DTE/DLCI) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-FrameRelayDteMIB::mscFrDteDlciReceivedOctets OID value, configure state conditions and alerts, and monitor any Nortel MscPassport multiservice switch (Frame Relay DTE/DLCI) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.101 | mscFrDte | Nortel-MsCarrier-MscPassport-FrameRelayDteMIB |
| 1.3.6.1.4.1.562.36.2.1.101.8 | mscFrDteDlci | Nortel-MsCarrier-MscPassport-FrameRelayDteMIB |
| 1.3.6.1.4.1.562.36.2.1.101.8.11 | mscFrDteDlciOperTable | Nortel-MsCarrier-MscPassport-FrameRelayDteMIB |
| 1.3.6.1.4.1.562.36.2.1.101.8.11.1 | mscFrDteDlciOperEntry | Nortel-MsCarrier-MscPassport-FrameRelayDteMIB |
| 1.3.6.1.4.1.562.36.2.1.101.8.11.1.10 | mscFrDteDlciReceivedOctets | Nortel-MsCarrier-MscPassport-FrameRelayDteMIB |