Description: The average number of bits to be transferred per second over the DLCI to the DCE. When this attribute is set to zero, the link speed will be used instead.
Setting this attribute will operationally override the corresponding provisional value on static entries.
What is mscFrDteDlciCommittedInformationRate?
This read-write value (0-48,000,000 bits/sec, default 64000) sets the Committed Information Rate -- the average throughput contracted for an operational DLCI (Dlci) across the DLCI to the DCE; leaving it at 0 tells the Passport to use the physical link speed instead. An admin sets this to match the bandwidth actually purchased from the carrier for this virtual circuit, since it is the baseline mscFrDteRateEnforcement measures bursts against. Because this is the operational (Dlci-level) copy of the attribute, setting it here overrides the corresponding provisioned value on the underlying static entry without changing that provisioned default.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.101.8.11.1.18 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-FrameRelayDteMIB::mscFrDteDlciCommittedInformationRate
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.101.8.11.1.18.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-FrameRelayDteMIB::mscFrDteDlciCommittedInformationRate.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.101.8.11.1.18.1 i <value>
Start monitoring Nortel MscPassport multiservice switch (Frame Relay DTE/DLCI) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-FrameRelayDteMIB::mscFrDteDlciCommittedInformationRate OID value, configure state conditions and alerts, and monitor any Nortel MscPassport multiservice switch (Frame Relay DTE/DLCI) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.101 | mscFrDte | Nortel-MsCarrier-MscPassport-FrameRelayDteMIB |
| 1.3.6.1.4.1.562.36.2.1.101.8 | mscFrDteDlci | Nortel-MsCarrier-MscPassport-FrameRelayDteMIB |
| 1.3.6.1.4.1.562.36.2.1.101.8.11 | mscFrDteDlciOperTable | Nortel-MsCarrier-MscPassport-FrameRelayDteMIB |
| 1.3.6.1.4.1.562.36.2.1.101.8.11.1 | mscFrDteDlciOperEntry | Nortel-MsCarrier-MscPassport-FrameRelayDteMIB |
| 1.3.6.1.4.1.562.36.2.1.101.8.11.1.18 | mscFrDteDlciCommittedInformationRate | Nortel-MsCarrier-MscPassport-FrameRelayDteMIB |