Nortel-MsCarrier-MscPassport-FabricMIB :: mscShelfFabricCardSecondaryControlBusStatus

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-FabricMIB › mscShelfFabricCardSecondaryControlBusStatus

mscShelfFabricCardSecondaryControlBusStatus

Module: Nortel-MsCarrier-MscPassport-FabricMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-FabricMIB::mscShelfFabricCardSecondaryControlBusStatus

OID (numeric): 1.3.6.1.4.1.562.36.2.1.13.5.12.1.4

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: This attribute indicates the state of the fabric's Secondary Control Bus (SCB). It may contain any combination of the following values: operational - The SCB is operational. locked - The SCB is being manually prevented from operating. noBus - The bus is down. failed - The SCB is disabled due to fault. bestEffort - The SCB is ignoring faults to allow a single channel to be operational. hardwareFailure - The bus failed due to an HSCX hardware error. parityOrCrcError - The bus failed due to a CRC error or a parity error. timeOutError - The bus failed due to an SSC message time-out. txOrRxError - The bus failed due to Tx or Rx problems. pollError - The bus failed an SCB poll. testMessageError - The bus failed a fabric card test.

Description of bits: operational(0) locked(1) noBus(2) failed(3) bestEffort(4) hardwareFailure(5) parityOrCrcError(6) timeOutError(7) txOrRxError(8) pollError(9) testMessageError(10)

What is mscShelfFabricCardSecondaryControlBusStatus?

A bitmask reporting the state of the fabric's Secondary Control Bus (SCB), e.g. operational, locked, or failed for a specific reason such as a parity/CRC error or a poll failure. Helps an admin diagnose a fabric-card control-plane problem separate from its data-plane switching function.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.13.5.12.1.4
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-FabricMIB::mscShelfFabricCardSecondaryControlBusStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.13.5.12.1.4.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-FabricMIB::mscShelfFabricCardSecondaryControlBusStatus.1

Start monitoring Nortel MSC Passport carrier-class WAN switch (shelf-card fabric-port state) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-FabricMIB::mscShelfFabricCardSecondaryControlBusStatus OID value, configure state conditions and alerts, and monitor any Nortel MSC Passport carrier-class WAN switch (shelf-card fabric-port state) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1.13mscShelfNortel-MsCarrier-MscPassport-BaseShelfMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.13.5mscShelfFabricCardNortel-MsCarrier-MscPassport-FabricMIB
1.3.6.1.4.1.562.36.2.1.13.5.12mscShelfFabricCardOperTableNortel-MsCarrier-MscPassport-FabricMIB
1.3.6.1.4.1.562.36.2.1.13.5.12.1mscShelfFabricCardOperEntryNortel-MsCarrier-MscPassport-FabricMIB
1.3.6.1.4.1.562.36.2.1.13.5.12.1.4mscShelfFabricCardSecondaryControlBusStatusNortel-MsCarrier-MscPassport-FabricMIB