Nortel-MsCarrier-MscPassport-AtmCoreMIB :: mscAtmIfVptVccVcdTmAbrMaxCellPerRmCell

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsNortel-MsCarrier-MscPassport-AtmCoreMIBmscAtmIfVptVccVcdTmAbrMaxCellPerRmCell

mscAtmIfVptVccVcdTmAbrMaxCellPerRmCell

Module: Nortel-MsCarrier-MscPassport-AtmCoreMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfVptVccVcdTmAbrMaxCellPerRmCell

OID (numeric): 1.3.6.1.4.1.562.36.2.1.114.9.20.2.2.2.110.1.15

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: This attribute specifies the maximum number of cells an ABR source may transmit for each forward Resource Management (RM) cell. The count of the cells transmitted includes data cells, OAM cells, backward RM cells, and the forward RM cell.

A value of 2 is not recommended although it is permitted according to the ATM Forum standard. When this attribute is set to a value of 2, it is possible that only one forward and one backward RM cell are repeatedly transmitted, and all data traffic is queued up indefinitely.

This attribute is ignored under all conditions where the operational attribute abrConnectionType has the value erSwitch.

VALUES (

16777216 = sameAsCa

)

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.114.9.20.2.2.2.110.1.15
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfVptVccVcdTmAbrMaxCellPerRmCell

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.114.9.20.2.2.2.110.1.15.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfVptVccVcdTmAbrMaxCellPerRmCell.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.114.9.20.2.2.2.110.1.15.1 i <value>

Start monitoring Nortel/Magellan Passport (MscPassport) ATM carrier switch (core ATM fabric) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfVptVccVcdTmAbrMaxCellPerRmCell OID value, configure state conditions and alerts, and monitor any Nortel/Magellan Passport (MscPassport) ATM carrier switch (core ATM fabric) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.114mscAtmIfNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.9mscAtmIfVptNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.9.20mscAtmIfVptVccNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.9.20.2mscAtmIfVptVccVcdNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.9.20.2.2mscAtmIfVptVccVcdTmNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.9.20.2.2.2mscAtmIfVptVccVcdTmAbrNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.9.20.2.2.2.110mscAtmIfVptVccVcdTmAbrProvTableNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.9.20.2.2.2.110.1mscAtmIfVptVccVcdTmAbrProvEntryNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.9.20.2.2.2.110.1.15mscAtmIfVptVccVcdTmAbrMaxCellPerRmCellNortel-MsCarrier-MscPassport-AtmCoreMIB