All MIBs › Nortel-MsCarrier-MscPassport-AtmCoreMIB › mscAtmIfVpcVpdPmSegLinkSideMeasurement
mscAtmIfVpcVpdPmSegLinkSideMeasurement
Module: Nortel-MsCarrier-MscPassport-AtmCoreMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfVpcVpdPmSegLinkSideMeasurement
OID (numeric): 1.3.6.1.4.1.562.36.2.1.114.4.2.3.100.1.2
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-write
Description: This attribute specifies the set of Performance Monitoring (PM) measurements on the link side configuration for the connection.
sameAsInterface means that the measurements specified by the segLinkSideMeasurement attribute of the AtmIf Pm component will be performed. No other values may be specified if sameAsInterface is selected. If the value is empty, no link side PM measurements are done.
The following are valid sets: (~sameAsInterface ~availabilityRatio ~cellLossRatio) (~sameAsInterface ~availabilityRatio cellLossRatio) (~sameAsInterface availabilityRatio ~cellLossRatio) (~sameAsInterface availabilityRatio cellLossRatio) (sameAsInterface ~availabilityRatio ~cellLossRatio)
Description of bits: availabilityRatio(0) cellLossRatio(1) sameAsInterface(2)
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.114.4.2.3.100.1.2 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfVpcVpdPmSegLinkSideMeasurement
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.114.4.2.3.100.1.2.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfVpcVpdPmSegLinkSideMeasurement.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.114.4.2.3.100.1.2.1 s <value>
Start monitoring Nortel/Magellan Passport (MscPassport) ATM carrier switch (core ATM fabric) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfVpcVpdPmSegLinkSideMeasurement OID value, configure state conditions and alerts, and monitor any Nortel/Magellan Passport (MscPassport) ATM carrier switch (core ATM fabric) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.114 | mscAtmIf | Nortel-MsCarrier-MscPassport-AtmCoreMIB |
| 1.3.6.1.4.1.562.36.2.1.114.4 | mscAtmIfVpc | Nortel-MsCarrier-MscPassport-AtmCoreMIB |
| 1.3.6.1.4.1.562.36.2.1.114.4.2 | mscAtmIfVpcVpd | Nortel-MsCarrier-MscPassport-AtmCoreMIB |
| 1.3.6.1.4.1.562.36.2.1.114.4.2.3 | mscAtmIfVpcVpdPm | Nortel-MsCarrier-MscPassport-AtmCoreMIB |
| 1.3.6.1.4.1.562.36.2.1.114.4.2.3.100 | mscAtmIfVpcVpdPmProvTable | Nortel-MsCarrier-MscPassport-AtmCoreMIB |
| 1.3.6.1.4.1.562.36.2.1.114.4.2.3.100.1 | mscAtmIfVpcVpdPmProvEntry | Nortel-MsCarrier-MscPassport-AtmCoreMIB |
| 1.3.6.1.4.1.562.36.2.1.114.4.2.3.100.1.2 | mscAtmIfVpcVpdPmSegLinkSideMeasurement | Nortel-MsCarrier-MscPassport-AtmCoreMIB |