Nortel-MsCarrier-MscPassport-AtmCoreMIB :: mscAtmIfVccVcdTmTransferCapabilityBbc

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsNortel-MsCarrier-MscPassport-AtmCoreMIBmscAtmIfVccVcdTmTransferCapabilityBbc

mscAtmIfVccVcdTmTransferCapabilityBbc

Module: Nortel-MsCarrier-MscPassport-AtmCoreMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfVccVcdTmTransferCapabilityBbc

OID (numeric): 1.3.6.1.4.1.562.36.2.1.114.5.2.2.100.1.72

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute specifies the transfer capability for this connection. Uni 3.0/3.1 traffic type and end-to-end timing parameters are mapped into this parameter as follows: 0: NoIndication, NoIndication 1: NoIndication, yes 2: NoIndication, no 5: CBR, yes 8: VBR, NoIndication 9: VBR, yes 10: VBR, no notApplicable specifies that the user does not want to specify the transfer capability. The CBR traffic type refers to traffic offered on services such as a constant bit rate video service or a circuit emulation. The VBR traffic type refers to traffic offered on services such as packetized audio and video, or data. The value no indication for traffic type is used if the user has not set the traffic type; similarly for end-to-end timing. The value yes for end-to-end timing indicates that end-to-end timing is required. The value no for end-to-end timing indicates that end-to-end timing is not required. The value derivedFromServiceCategory specifies that the actual value which is used for this connection is derived from the value of the atmServiceCategory. Either, this attribute must be set to derivedFromServiceCategory, or the atmServiceCategory attribute must be set to derivedFromBBC, but not both.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.114.5.2.2.100.1.72
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfVccVcdTmTransferCapabilityBbc

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.114.5.2.2.100.1.72.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfVccVcdTmTransferCapabilityBbc.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.114.5.2.2.100.1.72.1 i <value>

Start monitoring Nortel/Magellan Passport (MscPassport) ATM carrier switch (core ATM fabric) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfVccVcdTmTransferCapabilityBbc OID value, configure state conditions and alerts, and monitor any Nortel/Magellan Passport (MscPassport) ATM carrier switch (core ATM fabric) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.114mscAtmIfNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.5mscAtmIfVccNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.5.2mscAtmIfVccVcdNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.5.2.2mscAtmIfVccVcdTmNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.5.2.2.100mscAtmIfVccVcdTmProvTableNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.5.2.2.100.1mscAtmIfVccVcdTmProvEntryNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.5.2.2.100.1.72mscAtmIfVccVcdTmTransferCapabilityBbcNortel-MsCarrier-MscPassport-AtmCoreMIB