Nortel-MsCarrier-MscPassport-AtmCoreMIB :: mscAtmIfVccVcdTmBestEffort

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsNortel-MsCarrier-MscPassport-AtmCoreMIBmscAtmIfVccVcdTmBestEffort

mscAtmIfVccVcdTmBestEffort

Module: Nortel-MsCarrier-MscPassport-AtmCoreMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfVccVcdTmBestEffort

OID (numeric): 1.3.6.1.4.1.562.36.2.1.114.5.2.2.100.1.75

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute specifies the value of the best effort parameter in the ATM Traffic Descriptor Information Element. This attribute is only used for Soft PVC connections. It is one of the Broadband Bearer Capability attributes.

The value indicated implies that the quality of service for this connection is not guaranteed.

The value notIndicated implies that the quality of service for this connection is guaranteed.

The value derivedFromServiceCategory specifies that the actual value which is used for this connection is derived from the value of the atmServiceCategory. Either, this attribute must be set to derivedFromServiceCategory, or the atmServiceCategory attribute must be set to derivedFromBBC, but not both.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.114.5.2.2.100.1.75
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfVccVcdTmBestEffort

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.114.5.2.2.100.1.75.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfVccVcdTmBestEffort.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.114.5.2.2.100.1.75.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> mscAtmIfVccVcdTmBestEffort.1

Start monitoring Nortel/Magellan Passport (MscPassport) ATM carrier switch (core ATM fabric) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfVccVcdTmBestEffort OID value, configure state conditions and alerts, and monitor any Nortel/Magellan Passport (MscPassport) ATM carrier switch (core ATM fabric) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.114mscAtmIfNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.5mscAtmIfVccNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.5.2mscAtmIfVccVcdNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.5.2.2mscAtmIfVccVcdTmNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.5.2.2.100mscAtmIfVccVcdTmProvTableNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.5.2.2.100.1mscAtmIfVccVcdTmProvEntryNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.5.2.2.100.1.75mscAtmIfVccVcdTmBestEffortNortel-MsCarrier-MscPassport-AtmCoreMIB