Nortel-MsCarrier-MscPassport-AtmCoreMIB :: mscAtmIfFaultHoldOffTime

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsNortel-MsCarrier-MscPassport-AtmCoreMIBmscAtmIfFaultHoldOffTime

mscAtmIfFaultHoldOffTime

Module: Nortel-MsCarrier-MscPassport-AtmCoreMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfFaultHoldOffTime

OID (numeric): 1.3.6.1.4.1.562.36.2.1.114.110.1.100

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute specifies the delay before faults detected at the VP layer are propagated to the VC layer, and thus to the application using the connection.

If the value is 0 (zero), applications using a VirtualPathTerminator are immediately notified of faults detected by the VP. Using this value allows these applications to be advised of faults without requiring loopbacks on each Vcc. Typically, the application goes out of service when advised of a fault.

If the value is infinity, applications are not notified of VP layer faults. Using this value allows the applications to survive transient VP layer fault conditions.

The value chosen applies only to Vpts and Vccs directly beneath a Vpt.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.114.110.1.100
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfFaultHoldOffTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.114.110.1.100.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfFaultHoldOffTime.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.114.110.1.100.1 i <value>

Start monitoring Nortel/Magellan Passport (MscPassport) ATM carrier switch (core ATM fabric) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-AtmCoreMIB::mscAtmIfFaultHoldOffTime OID value, configure state conditions and alerts, and monitor any Nortel/Magellan Passport (MscPassport) ATM carrier switch (core ATM fabric) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.114mscAtmIfNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.110mscAtmIfProvTableNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.110.1mscAtmIfProvEntryNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.110.1.100mscAtmIfFaultHoldOffTimeNortel-MsCarrier-MscPassport-AtmCoreMIB