Nortel-MsCarrier-MscPassport-AtmBearerServiceMIB :: mscAtmIfVccNrpConnectionPointType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsNortel-MsCarrier-MscPassport-AtmBearerServiceMIBmscAtmIfVccNrpConnectionPointType

mscAtmIfVccNrpConnectionPointType

Module: Nortel-MsCarrier-MscPassport-AtmBearerServiceMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-AtmBearerServiceMIB::mscAtmIfVccNrpConnectionPointType

OID (numeric): 1.3.6.1.4.1.562.36.2.1.114.5.4.100.1.20

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute specifies the connection point type desired for a Nrp component. The actual connection point type value is visible in the parent component's connectionPointType attribute.

The desired connection point type can be specified directly as a segmentEndPoint or connectingPoint. If autoConfigure is specified, the switch will select the connection point type based on the type attribute of the associated AtmIf, choosing segmentEndPoint for a UNI-type ATM interface and connectingPoint for a PPI-type ATM interface.

It is obsoleted. The value is mapped into oamSegmentBoundary attribute. segmentEndPoint is mapped into yes. connectingPoint is mapped into no. autoConfigure is mapped into sameAsInterface.

What is mscAtmIfVccNrpConnectionPointType?

An obsolete attribute that used to specify segment end point or connecting point OAM behavior for this Vcc Nrp, now superseded by mscAtmIfVccNrpOamSegmentBoundary. An admin should set the OAM segment boundary attribute instead when configuring current firmware.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.114.5.4.100.1.20
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmBearerServiceMIB::mscAtmIfVccNrpConnectionPointType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.114.5.4.100.1.20.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmBearerServiceMIB::mscAtmIfVccNrpConnectionPointType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.114.5.4.100.1.20.1 i <value>

Start monitoring Nortel MsCarrier MscPassport ATM switch (ATM bearer service/VPC NRP) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-AtmBearerServiceMIB::mscAtmIfVccNrpConnectionPointType OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier MscPassport ATM switch (ATM bearer service/VPC NRP) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1.114mscAtmIfNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.5mscAtmIfVccNortel-MsCarrier-MscPassport-AtmCoreMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.114.5.4mscAtmIfVccNrpNortel-MsCarrier-MscPassport-AtmBearerServiceMIB
1.3.6.1.4.1.562.36.2.1.114.5.4.100mscAtmIfVccNrpProvTableNortel-MsCarrier-MscPassport-AtmBearerServiceMIB
1.3.6.1.4.1.562.36.2.1.114.5.4.100.1mscAtmIfVccNrpProvEntryNortel-MsCarrier-MscPassport-AtmBearerServiceMIB
1.3.6.1.4.1.562.36.2.1.114.5.4.100.1.20mscAtmIfVccNrpConnectionPointTypeNortel-MsCarrier-MscPassport-AtmBearerServiceMIB