Nortel-MsCarrier-MscPassport-AtmBaseMIB :: mscLpEngArcOvRxCellMemoryAllocation

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-AtmBaseMIB › mscLpEngArcOvRxCellMemoryAllocation

mscLpEngArcOvRxCellMemoryAllocation

Module: Nortel-MsCarrier-MscPassport-AtmBaseMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-AtmBaseMIB::mscLpEngArcOvRxCellMemoryAllocation

OID (numeric): 1.3.6.1.4.1.562.36.2.1.12.23.5.2.10.1.4

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: This attribute specifies the fraction of the receive memory which should be allocated to the reception of cells on an FP. The remaining receive memory is allocated for the reception of frames. Frame memory is used for trunks, ATM VCC testing and for inter- card communication. Cell memory is used for Atm Bearer Service, ATM SVCs and ATM PVCs.

There is an absolute minimum quantity of frame buffers which is required by ATM software on the FP. If the value of this attribute is smaller than the absolute minimum, the ATM software allocates the minimum required, rather than the actual number requested.

The actual percentage of the receive memory allocated to the receive cell memory is indicated by the Arc rxCellMemoryAllocation attribute. A difference between the provisioned and the operational values may exist due to the requirement for a minimum number of frame buffers or rounding during computation within the FP.

What is mscLpEngArcOvRxCellMemoryAllocation?

Sets the fraction of receive memory on this FP allocated to cell traffic versus frame traffic, default 20%; the operational counterpart mscLpEngArcRxCellMemoryAllocation reports what was actually applied.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.12.23.5.2.10.1.4
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmBaseMIB::mscLpEngArcOvRxCellMemoryAllocation

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.12.23.5.2.10.1.4.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmBaseMIB::mscLpEngArcOvRxCellMemoryAllocation.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.12.23.5.2.10.1.4.1 i <value>

Start monitoring Nortel MsCarrier Passport switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-AtmBaseMIB::mscLpEngArcOvRxCellMemoryAllocation OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier Passport switches from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1.12mscLpNortel-MsCarrier-MscPassport-LogicalProcessorMIB
1.3.6.1.4.1.562.36.2.1.12.23mscLpEngNortel-MsCarrier-MscPassport-LogicalProcessorMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.12.23.5mscLpEngArcNortel-MsCarrier-MscPassport-AtmBaseMIB
1.3.6.1.4.1.562.36.2.1.12.23.5.2mscLpEngArcOvNortel-MsCarrier-MscPassport-AtmBaseMIB
1.3.6.1.4.1.562.36.2.1.12.23.5.2.10mscLpEngArcOvProvTableNortel-MsCarrier-MscPassport-AtmBaseMIB
1.3.6.1.4.1.562.36.2.1.12.23.5.2.10.1mscLpEngArcOvProvEntryNortel-MsCarrier-MscPassport-AtmBaseMIB
1.3.6.1.4.1.562.36.2.1.12.23.5.2.10.1.4mscLpEngArcOvRxCellMemoryAllocationNortel-MsCarrier-MscPassport-AtmBaseMIB