All MIBs › Nortel-MsCarrier-MscPassport-AtmBaseMIB › mscLpEngArcAqmOvConnectionPoolCapacity
mscLpEngArcAqmOvConnectionPoolCapacity
Module: Nortel-MsCarrier-MscPassport-AtmBaseMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-AtmBaseMIB::mscLpEngArcAqmOvConnectionPoolCapacity
OID (numeric): 1.3.6.1.4.1.562.36.2.1.12.23.5.4.2.10.1.1
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-write
Description: This attribute specifies the maximum number of connections (VCC, VPC and VPT) that can be configured on the AQM instance of the LogicalProcessor.
The value of the attribute restricts the sum of the (maxVccs + maxVpcs +(maxVpts * 3)) across all AtmIfs bound to this AQM instance. Note that 3 connections are used for each standard Vpt and 2 for each basic Vpt.
The value of this attribute should be less than than or equal to totalConnectionPoolCapacity of the Arc component.
The default value derivedFromArc is obtained using the following equation:
totalConnectionPoolCapacity / number of AQM component on FP.
VALUES (
0 = derivedFromArc
)
What is mscLpEngArcAqmOvConnectionPoolCapacity?
Sets the maximum ATM connections (VCC, VPC, VPT) allowed on this AQM instance; the default value 0 (derivedFromArc) splits the FP-wide totalConnectionPoolCapacity evenly across the AQM instances on the card instead of using a fixed number.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.12.23.5.4.2.10.1.1 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmBaseMIB::mscLpEngArcAqmOvConnectionPoolCapacity
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.12.23.5.4.2.10.1.1.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmBaseMIB::mscLpEngArcAqmOvConnectionPoolCapacity.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.12.23.5.4.2.10.1.1.1 i <value>
Start monitoring Nortel MsCarrier Passport switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-AtmBaseMIB::mscLpEngArcAqmOvConnectionPoolCapacity OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier Passport switches from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1.12 | mscLp | Nortel-MsCarrier-MscPassport-LogicalProcessorMIB |
| 1.3.6.1.4.1.562.36.2.1.12.23 | mscLpEng | Nortel-MsCarrier-MscPassport-LogicalProcessorMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.12.23.5 | mscLpEngArc | Nortel-MsCarrier-MscPassport-AtmBaseMIB |
| 1.3.6.1.4.1.562.36.2.1.12.23.5.4 | mscLpEngArcAqm | Nortel-MsCarrier-MscPassport-AtmBaseMIB |
| 1.3.6.1.4.1.562.36.2.1.12.23.5.4.2 | mscLpEngArcAqmOv | Nortel-MsCarrier-MscPassport-AtmBaseMIB |
| 1.3.6.1.4.1.562.36.2.1.12.23.5.4.2.10 | mscLpEngArcAqmOvProvTable | Nortel-MsCarrier-MscPassport-AtmBaseMIB |
| 1.3.6.1.4.1.562.36.2.1.12.23.5.4.2.10.1 | mscLpEngArcAqmOvProvEntry | Nortel-MsCarrier-MscPassport-AtmBaseMIB |
| 1.3.6.1.4.1.562.36.2.1.12.23.5.4.2.10.1.1 | mscLpEngArcAqmOvConnectionPoolCapacity | Nortel-MsCarrier-MscPassport-AtmBaseMIB |