All MIBs › Nortel-Magellan-Passport-X25TraceRcvrMIB › traceSessionX25VcOutOfRangeFrmFromSubnet
traceSessionX25VcOutOfRangeFrmFromSubnet
Module: Nortel-Magellan-Passport-X25TraceRcvrMIB
OID (symbolic): Nortel-Magellan-Passport-X25TraceRcvrMIB::traceSessionX25VcOutOfRangeFrmFromSubnet
OID (numeric): 1.3.6.1.4.1.562.2.4.1.106.3.2.2.12.1.2
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-only
Description: This attribute counts the number of subnet frames discarded due to the sequence number being out of range. Two Categories apply for the General Vc 1) lost Acks (previous Range) 2) unexpected Packets (next Range) Vc internally maintains its own sequence number of packet order and sequencing. Due to packet retransmission, Vc may receive duplicate packets that have the same Vc internal sequence number. Only 1 copy is accepted by the Vc and other copies of the same packets are detected through this count. This attribute can be used to record the frequency of packet retransmission due to Vc and other part of the subnet.
What is traceSessionX25VcOutOfRangeFrmFromSubnet?
Counts subnet frames discarded because their sequence number fell outside the Vc's expected range (either lost acks in the previous range or unexpected packets in the next range); a rising count points to packet retransmission happening somewhere in the Vc or subnet.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.106.3.2.2.12.1.2 snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-X25TraceRcvrMIB::traceSessionX25VcOutOfRangeFrmFromSubnet
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.106.3.2.2.12.1.2.1 snmpget -v2c -c public <target> Nortel-Magellan-Passport-X25TraceRcvrMIB::traceSessionX25VcOutOfRangeFrmFromSubnet.1
Start monitoring Nortel Magellan Passport X.25/WAN switch (X.25 packet trace receiver) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-X25TraceRcvrMIB::traceSessionX25VcOutOfRangeFrmFromSubnet OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport X.25/WAN switch (X.25 packet trace receiver) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.2 | magellan | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.2.4 | passport | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.2.4.1 | components | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.2.4.1.106 | trace | Nortel-Magellan-Passport-TraceBaseMIB |
| 1.3.6.1.4.1.562.2.4.1.106.3 | traceSession | Nortel-Magellan-Passport-TraceBaseMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.2.4.1.106.3.2 | traceSessionX25 | Nortel-Magellan-Passport-X25TraceRcvrMIB |
| 1.3.6.1.4.1.562.2.4.1.106.3.2.2 | traceSessionX25Vc | Nortel-Magellan-Passport-X25TraceRcvrMIB |
| 1.3.6.1.4.1.562.2.4.1.106.3.2.2.12 | traceSessionX25VcStatsTable | Nortel-Magellan-Passport-X25TraceRcvrMIB |
| 1.3.6.1.4.1.562.2.4.1.106.3.2.2.12.1 | traceSessionX25VcStatsEntry | Nortel-Magellan-Passport-X25TraceRcvrMIB |
| 1.3.6.1.4.1.562.2.4.1.106.3.2.2.12.1.2 | traceSessionX25VcOutOfRangeFrmFromSubnet | Nortel-Magellan-Passport-X25TraceRcvrMIB |