All MIBs › Nortel-Magellan-Passport-Frf5EpMIB › mcsMgrFrf5EpGEpLmiProcedures
mcsMgrFrf5EpGEpLmiProcedures
Module: Nortel-Magellan-Passport-Frf5EpMIB
OID (symbolic): Nortel-Magellan-Passport-Frf5EpMIB::mcsMgrFrf5EpGEpLmiProcedures
OID (numeric): 1.3.6.1.4.1.562.2.4.1.122.14.3.2.10.1.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This attribute selects the procedures to be used for the Local Management Interface. The following are the supported procedures:
none: no Local Management Interface procedures are running on the ATM VCC. This accomodates remote interworking functions which do not implement LMI procedures. In this case, the remaining attributes of this group will be ignored.
ccitt: Local Management Interface procedures from the CCITT specification are supported. Dlci/0 is used for the LMI protocol, to comply with FRF.5.
ansi: Local Management Interface procedures from the ANSI specification are supported. DLCI 0 is used for the LMI protocol.
What is mcsMgrFrf5EpGEpLmiProcedures?
Selects which Local Management Interface procedure this endpoint uses: none(0) for remote interworking functions without LMI, ansi(2), or ccitt(3, the default, using DLCI 0 for the LMI protocol per FRF.5). Admins set this to match whatever LMI variant the remote Frame Relay equipment expects, since a mismatch prevents proper PVC status reporting.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.122.14.3.2.10.1.1 snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-Frf5EpMIB::mcsMgrFrf5EpGEpLmiProcedures
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.122.14.3.2.10.1.1.1 snmpget -v2c -c public <target> Nortel-Magellan-Passport-Frf5EpMIB::mcsMgrFrf5EpGEpLmiProcedures.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.2.4.1.122.14.3.2.10.1.1.1 i <value>
Start monitoring Nortel Magellan Passport Frame Relay/ATM interworking switch (FRF.5) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-Frf5EpMIB::mcsMgrFrf5EpGEpLmiProcedures OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport Frame Relay/ATM interworking switch (FRF.5) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.2 | magellan | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.2.4 | passport | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.2.4.1 | components | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.2.4.1.122 | mcsMgr | Nortel-Magellan-Passport-McsMgrMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.2.4.1.122.14 | mcsMgrFrf5EpG | Nortel-Magellan-Passport-Frf5EpMIB |
| 1.3.6.1.4.1.562.2.4.1.122.14.3 | mcsMgrFrf5EpGEp | Nortel-Magellan-Passport-Frf5EpMIB |
| 1.3.6.1.4.1.562.2.4.1.122.14.3.2 | mcsMgrFrf5EpGEpLmi | Nortel-Magellan-Passport-Frf5EpMIB |
| 1.3.6.1.4.1.562.2.4.1.122.14.3.2.10 | mcsMgrFrf5EpGEpLmiParmsTable | Nortel-Magellan-Passport-Frf5EpMIB |
| 1.3.6.1.4.1.562.2.4.1.122.14.3.2.10.1 | mcsMgrFrf5EpGEpLmiParmsEntry | Nortel-Magellan-Passport-Frf5EpMIB |
| 1.3.6.1.4.1.562.2.4.1.122.14.3.2.10.1.1 | mcsMgrFrf5EpGEpLmiProcedures | Nortel-Magellan-Passport-Frf5EpMIB |