Nortel-Magellan-Passport-Frf5EpMIB :: mcsMgrFrf5EpGEpEpdCommittedInformationRate

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-Magellan-Passport-Frf5EpMIB › mcsMgrFrf5EpGEpEpdCommittedInformationRate

mcsMgrFrf5EpGEpEpdCommittedInformationRate

Module: Nortel-Magellan-Passport-Frf5EpMIB

OID (symbolic): Nortel-Magellan-Passport-Frf5EpMIB::mcsMgrFrf5EpGEpEpdCommittedInformationRate

OID (numeric): 1.3.6.1.4.1.562.2.4.1.122.14.3.3.10.1.5

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: This attribute specifies the committed information rate (CIR), and represents the rate at which the network FRF.5 ATM VCC agrees to transfer information under normal conditions. A conservative CIR value would be the sum of the CIRs of all the individual FrAtm Dlcis multiplexed by the VCC. The cir is converted into ATM service parameters according to the conversion policy specified by the connectionTransferPriority attribute. The conversion policy is defined under the ModuleData FrameRelayService AtmNetworking TransferPriority/n component.

What is mcsMgrFrf5EpGEpEpdCommittedInformationRate?

Sets the Committed Information Rate (CIR, default 64000 bps), the rate this endpoint's FRF.5 ATM VCC agrees to transfer under normal conditions; a conservative value is the sum of the CIRs of all the individual Frame Relay DLCIs it multiplexes. This is the guaranteed baseline throughput admins provision for the circuit, converted into ATM PCR/SCR/MBS via the endpoint's conversion policy.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.122.14.3.3.10.1.5
snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-Frf5EpMIB::mcsMgrFrf5EpGEpEpdCommittedInformationRate

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.122.14.3.3.10.1.5.1
snmpget -v2c -c public <target> Nortel-Magellan-Passport-Frf5EpMIB::mcsMgrFrf5EpGEpEpdCommittedInformationRate.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.2.4.1.122.14.3.3.10.1.5.1 i <value>

Start monitoring Nortel Magellan Passport Frame Relay/ATM interworking switch (FRF.5) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-Frf5EpMIB::mcsMgrFrf5EpGEpEpdCommittedInformationRate OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport Frame Relay/ATM interworking switch (FRF.5) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.2magellanNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4passportNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1componentsNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1.122mcsMgrNortel-Magellan-Passport-McsMgrMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.2.4.1.122.14mcsMgrFrf5EpGNortel-Magellan-Passport-Frf5EpMIB
1.3.6.1.4.1.562.2.4.1.122.14.3mcsMgrFrf5EpGEpNortel-Magellan-Passport-Frf5EpMIB
1.3.6.1.4.1.562.2.4.1.122.14.3.3mcsMgrFrf5EpGEpEpdNortel-Magellan-Passport-Frf5EpMIB
1.3.6.1.4.1.562.2.4.1.122.14.3.3.10mcsMgrFrf5EpGEpEpdProvTableNortel-Magellan-Passport-Frf5EpMIB
1.3.6.1.4.1.562.2.4.1.122.14.3.3.10.1mcsMgrFrf5EpGEpEpdProvEntryNortel-Magellan-Passport-Frf5EpMIB
1.3.6.1.4.1.562.2.4.1.122.14.3.3.10.1.5mcsMgrFrf5EpGEpEpdCommittedInformationRateNortel-Magellan-Passport-Frf5EpMIB