Nortel-Magellan-Passport-Frf5EpMIB :: mcsMgrFrf5EpGEpEpdCommittedBurstSize

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-Magellan-Passport-Frf5EpMIB › mcsMgrFrf5EpGEpEpdCommittedBurstSize

mcsMgrFrf5EpGEpEpdCommittedBurstSize

Module: Nortel-Magellan-Passport-Frf5EpMIB

OID (symbolic): Nortel-Magellan-Passport-Frf5EpMIB::mcsMgrFrf5EpGEpEpdCommittedBurstSize

OID (numeric): 1.3.6.1.4.1.562.2.4.1.122.14.3.3.10.1.7

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: This attribute specifies the committed burst size (Bc), and represents the amount of data that the network FRF.5 ATM VCC agrees to transfer under normal conditions. A conservative Bc value would be the sum of the Bcs of all the individual FrAtm Dlcis multiplexed by the VCC. The bc is converted into ATM service parameters according to the conversion policy specified by the connectionTransferPriority attribute. The conversion policy is defined under the ModuleData FrameRelayService AtmNetworking TransferPriority/n component.

What is mcsMgrFrf5EpGEpEpdCommittedBurstSize?

Sets the Committed Burst Size (Bc, default 16000), the amount of data this endpoint's FRF.5 ATM VCC agrees to transfer under normal conditions; a conservative value is the sum of the Bc values of the DLCIs it multiplexes. This value feeds the traffic-parameter conversion policy that derives the connection's ATM MBS.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.122.14.3.3.10.1.7
snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-Frf5EpMIB::mcsMgrFrf5EpGEpEpdCommittedBurstSize

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.122.14.3.3.10.1.7.1
snmpget -v2c -c public <target> Nortel-Magellan-Passport-Frf5EpMIB::mcsMgrFrf5EpGEpEpdCommittedBurstSize.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.2.4.1.122.14.3.3.10.1.7.1 i <value>

Start monitoring Nortel Magellan Passport Frame Relay/ATM interworking switch (FRF.5) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-Frf5EpMIB::mcsMgrFrf5EpGEpEpdCommittedBurstSize OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport Frame Relay/ATM interworking switch (FRF.5) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.2magellanNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4passportNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1componentsNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1.122mcsMgrNortel-Magellan-Passport-McsMgrMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.2.4.1.122.14mcsMgrFrf5EpGNortel-Magellan-Passport-Frf5EpMIB
1.3.6.1.4.1.562.2.4.1.122.14.3mcsMgrFrf5EpGEpNortel-Magellan-Passport-Frf5EpMIB
1.3.6.1.4.1.562.2.4.1.122.14.3.3mcsMgrFrf5EpGEpEpdNortel-Magellan-Passport-Frf5EpMIB
1.3.6.1.4.1.562.2.4.1.122.14.3.3.10mcsMgrFrf5EpGEpEpdProvTableNortel-Magellan-Passport-Frf5EpMIB
1.3.6.1.4.1.562.2.4.1.122.14.3.3.10.1mcsMgrFrf5EpGEpEpdProvEntryNortel-Magellan-Passport-Frf5EpMIB
1.3.6.1.4.1.562.2.4.1.122.14.3.3.10.1.7mcsMgrFrf5EpGEpEpdCommittedBurstSizeNortel-Magellan-Passport-Frf5EpMIB