Nortel-Magellan-Passport-FrameRelayUniMIB :: frUniSigX213IeHandling

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-Magellan-Passport-FrameRelayUniMIB › frUniSigX213IeHandling

frUniSigX213IeHandling

Module: Nortel-Magellan-Passport-FrameRelayUniMIB

OID (symbolic): Nortel-Magellan-Passport-FrameRelayUniMIB::frUniSigX213IeHandling

OID (numeric): 1.3.6.1.4.1.562.2.4.1.71.6.12.1.17

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The x213IeHandling attribute specifies how Frame Relay handles the X.213 Priority IE when it is in the Q.933 setup message.

When the attribute is set to notSupported, the X.213 Priority IE will not be recognized in the setup message. A Q.933 status message will be sent to the calling DTE, with the indication that an unrecognized IE was encountered. The call setup then proceeds as normal, and the X.213 Priority IE does not appear in the setup message at the called end.

When the attribute is set to proprietary, and the X.213 Priority IE is present in the Q.933 setup message, it will be recognized. If there is no Frame Transfer Priority IE in the setup message, the first data byte of the X.213 Priority IE is used to select the transfer and discard priority values for the connection and the X.213 Priority IE is signaled to the called end in the setup message. If the Frame Transfer Priority IE is present in the Q.933 setup message, its value is used to select the transfer priority, the discard priority is taken from the FRUNI Dna component, and the X.213 Priority IE is ignored.

Refer to the related Application Note for further details before setting the attribute value to proprietary.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.71.6.12.1.17
snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-FrameRelayUniMIB::frUniSigX213IeHandling

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.71.6.12.1.17.1
snmpget -v2c -c public <target> Nortel-Magellan-Passport-FrameRelayUniMIB::frUniSigX213IeHandling.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.2.4.1.71.6.12.1.17.1 i <value>

Start monitoring Nortel Magellan Passport packet switch (Frame Relay UNI/DLCI) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-FrameRelayUniMIB::frUniSigX213IeHandling OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport packet switch (Frame Relay UNI/DLCI) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.2magellanNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4passportNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1componentsNortel-Magellan-Passport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.2.4.1.71frUniNortel-Magellan-Passport-FrameRelayUniMIB
1.3.6.1.4.1.562.2.4.1.71.6frUniSigNortel-Magellan-Passport-FrameRelayUniMIB
1.3.6.1.4.1.562.2.4.1.71.6.12frUniSigServParmsTableNortel-Magellan-Passport-FrameRelayUniMIB
1.3.6.1.4.1.562.2.4.1.71.6.12.1frUniSigServParmsEntryNortel-Magellan-Passport-FrameRelayUniMIB
1.3.6.1.4.1.562.2.4.1.71.6.12.1.17frUniSigX213IeHandlingNortel-Magellan-Passport-FrameRelayUniMIB