Nortel-Magellan-Passport-FrameRelayUniMIB :: frUniSigIFramesRcvdDiscarded

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-Magellan-Passport-FrameRelayUniMIB › frUniSigIFramesRcvdDiscarded

frUniSigIFramesRcvdDiscarded

Module: Nortel-Magellan-Passport-FrameRelayUniMIB

OID (symbolic): Nortel-Magellan-Passport-FrameRelayUniMIB::frUniSigIFramesRcvdDiscarded

OID (numeric): 1.3.6.1.4.1.562.2.4.1.71.6.18.1.8

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: This attribute counts the number of SVC I-frames received but have been discarded. The discard reasons are: 1. incorrect frame size 2. frame is out of sequence 3. frame received while the network side of the SVC data link layer is not in the informationTransfer or waitingAck state.

When this count reaches maximum, it wraps to zero.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.71.6.18.1.8
snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-FrameRelayUniMIB::frUniSigIFramesRcvdDiscarded

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.71.6.18.1.8.1
snmpget -v2c -c public <target> Nortel-Magellan-Passport-FrameRelayUniMIB::frUniSigIFramesRcvdDiscarded.1

Start monitoring Nortel Magellan Passport packet switch (Frame Relay UNI/DLCI) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-FrameRelayUniMIB::frUniSigIFramesRcvdDiscarded OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport packet switch (Frame Relay UNI/DLCI) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.2magellanNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4passportNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1componentsNortel-Magellan-Passport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.2.4.1.71frUniNortel-Magellan-Passport-FrameRelayUniMIB
1.3.6.1.4.1.562.2.4.1.71.6frUniSigNortel-Magellan-Passport-FrameRelayUniMIB
1.3.6.1.4.1.562.2.4.1.71.6.18frUniSigLapfStatsTableNortel-Magellan-Passport-FrameRelayUniMIB
1.3.6.1.4.1.562.2.4.1.71.6.18.1frUniSigLapfStatsEntryNortel-Magellan-Passport-FrameRelayUniMIB
1.3.6.1.4.1.562.2.4.1.71.6.18.1.8frUniSigIFramesRcvdDiscardedNortel-Magellan-Passport-FrameRelayUniMIB