Type: Unsigned32

Access: read-write

Description: This attribute is the allowable error rate beyond which the Unacknowledged, Utp, or FrAccess component can be degraded if it persists for a duration longer than the maximumErrorInterval. The threshold is expressed as a percentage of number of errored frames in the last interval per number of frames received in the last interval. The exception to this is a value of zero, which indicates that the mechanism is completely disabled. The configurable values are: 0 = the mechanism is completely disabled 1 = 1/(2**1) 2 = 1/(2**2) 3 = 1/(2**3) : 10 = 1/(2**10)

What is dpnGateFrAccessReceiveErrorSensitivity?

The error-rate threshold (0-10, default 3, expressed as 1/2^n of frames received) beyond which this FrAccess link can be flagged as degraded if it persists past dpnGateFrAccessMaximumErroredInterval; 0 disables the mechanism entirely.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.61.4.10.1.2
snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-FraDpnTrunksMIB::dpnGateFrAccessReceiveErrorSensitivity

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.61.4.10.1.2.1
snmpget -v2c -c public <target> Nortel-Magellan-Passport-FraDpnTrunksMIB::dpnGateFrAccessReceiveErrorSensitivity.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.2.4.1.61.4.10.1.2.1 i <value>

Start monitoring Nortel Magellan Passport multiservice WAN switch (Frame Relay over DPN trunks) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-FraDpnTrunksMIB::dpnGateFrAccessReceiveErrorSensitivity OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport multiservice WAN switch (Frame Relay over DPN trunks) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.2magellanNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4passportNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1componentsNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1.61dpnGateNortel-Magellan-Passport-DpnTrunksMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.2.4.1.61.4dpnGateFrAccessNortel-Magellan-Passport-FraDpnTrunksMIB
1.3.6.1.4.1.562.2.4.1.61.4.10dpnGateFrAccessProvTableNortel-Magellan-Passport-FraDpnTrunksMIB
1.3.6.1.4.1.562.2.4.1.61.4.10.1dpnGateFrAccessProvEntryNortel-Magellan-Passport-FraDpnTrunksMIB
1.3.6.1.4.1.562.2.4.1.61.4.10.1.2dpnGateFrAccessReceiveErrorSensitivityNortel-Magellan-Passport-FraDpnTrunksMIB