Nortel-Magellan-Passport-AtmIispMIB :: atmIfVptIispAccountCollection

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-Magellan-Passport-AtmIispMIB › atmIfVptIispAccountCollection

atmIfVptIispAccountCollection

Module: Nortel-Magellan-Passport-AtmIispMIB

OID (symbolic): Nortel-Magellan-Passport-AtmIispMIB::atmIfVptIispAccountCollection

OID (numeric): 1.3.6.1.4.1.562.2.4.1.114.9.6.11.1.1

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: This attribute is used to turn accounting on or off for SVC and SPVC connections. It also specifies the reason(s) for which accounting data is collected: billing, test, study, audit, or force.

If the set of reasons is not empty then accounting records will be generated by this interface in the following situations: - on a TODA changeover if TODA is enabled; - every 12 hours (per connection) if TODA is disabled; - on every call clear (a call record with final cell counts).

If none of the reasons is present, then accounting will be suppressed.

The reason for collection is recorded in the accounting record, in the attribute callingCollectReason or calledCollectReason as appropriate.

Description of bits: bill(0) test(1) study(2) audit(3) force(4)

What is atmIfVptIispAccountCollection?

Turns accounting on or off for SVC and SPVC connections on this virtual path and specifies the reasons (billing, test, study, audit, or force) for which records are collected, exactly as atmIfIispAccountCollection does for a physical interface.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.114.9.6.11.1.1
snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-AtmIispMIB::atmIfVptIispAccountCollection

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.114.9.6.11.1.1.1
snmpget -v2c -c public <target> Nortel-Magellan-Passport-AtmIispMIB::atmIfVptIispAccountCollection.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.2.4.1.114.9.6.11.1.1.1 s <value>

Start monitoring Nortel Magellan Passport ATM switch (IISP inter-switch signaling) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-AtmIispMIB::atmIfVptIispAccountCollection OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport ATM switch (IISP inter-switch signaling) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.2magellanNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4passportNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1componentsNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1.114atmIfNortel-Magellan-Passport-AtmCoreMIB
1.3.6.1.4.1.562.2.4.1.114.9atmIfVptNortel-Magellan-Passport-AtmCoreMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.2.4.1.114.9.6atmIfVptIispNortel-Magellan-Passport-AtmIispMIB
1.3.6.1.4.1.562.2.4.1.114.9.6.11atmIfVptIispAcctOptTableNortel-Magellan-Passport-AtmIispMIB
1.3.6.1.4.1.562.2.4.1.114.9.6.11.1atmIfVptIispAcctOptEntryNortel-Magellan-Passport-AtmIispMIB
1.3.6.1.4.1.562.2.4.1.114.9.6.11.1.1atmIfVptIispAccountCollectionNortel-Magellan-Passport-AtmIispMIB