NTNTECH-INTERFACE-MODULE-CONFIGURATION-MIB :: ifCfgVLANIdEnd

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsNTNTECH-INTERFACE-MODULE-CONFIGURATION-MIBifCfgVLANIdEnd

ifCfgVLANIdEnd

Module: NTNTECH-INTERFACE-MODULE-CONFIGURATION-MIB

OID (symbolic): NTNTECH-INTERFACE-MODULE-CONFIGURATION-MIB::ifCfgVLANIdEnd

OID (numeric): 1.3.6.1.4.1.8059.1.2.1.1.1.2.2.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The value assigned to a port which designates the end of a VLAN ID range.

What is ifCfgVLANIdEnd?

This read-write value (0-4085) sets the ending VLAN ID of one of a port's (up to ten) configured VLAN ID ranges. An admin configures this together with ifCfgVLANIdStart to define the upper bound of the VLAN tag range for that port.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8059.1.2.1.1.1.2.2.1.5
snmpwalk -v2c -c public <target> NTNTECH-INTERFACE-MODULE-CONFIGURATION-MIB::ifCfgVLANIdEnd

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8059.1.2.1.1.1.2.2.1.5.1
snmpget -v2c -c public <target> NTNTECH-INTERFACE-MODULE-CONFIGURATION-MIB::ifCfgVLANIdEnd.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.8059.1.2.1.1.1.2.2.1.5.1 i <value>

Start monitoring Paradyne nTech DSLAMs/access multiplexers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NTNTECH-INTERFACE-MODULE-CONFIGURATION-MIB::ifCfgVLANIdEnd OID value, configure state conditions and alerts, and monitor any Paradyne nTech DSLAMs/access multiplexers from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8059ntntechRootMIBNTNTECH-ROOT-MIB
1.3.6.1.4.1.8059.1ntntechNamingTreeNTNTECH-ROOT-MIB
1.3.6.1.4.1.8059.1.2ntntechInterfaceModuleNTNTECH-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8059.1.2.1ntntechInterfaceModuleConfigurationMIBNTNTECH-INTERFACE-MODULE-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.2.1.1ifModCfgMIBObjectsNTNTECH-INTERFACE-MODULE-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.2.1.1.1ifModCfgParameterConfigurationNTNTECH-INTERFACE-MODULE-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.2.1.1.1.2prmCfgInterfacePortNTNTECH-INTERFACE-MODULE-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.2.1.1.1.2.2ifCfgPortVLANTableNTNTECH-INTERFACE-MODULE-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.2.1.1.1.2.2.1ifCfgPortVLANEntryNTNTECH-INTERFACE-MODULE-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.2.1.1.1.2.2.1.5ifCfgVLANIdEndNTNTECH-INTERFACE-MODULE-CONFIGURATION-MIB