All MIBs › NTNTECH-CHASSIS-CONFIGURATION-MIB › uimCfgT1MumIndex
uimCfgT1MumIndex
Module: NTNTECH-CHASSIS-CONFIGURATION-MIB
OID (symbolic): NTNTECH-CHASSIS-CONFIGURATION-MIB::uimCfgT1MumIndex
OID (numeric): 1.3.6.1.4.1.8059.1.1.1.1.1.1.3.2.1.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Translates to the physical slot number that a MUM200-2/2000-2 module
exists within a chassis. The Mini/Micro DSLAMs' physical location is
set to 1 by default. See below,
chassis type physical location(s) translation
------------ --------------------------------
IPD12000 MUM in slots 13,14 = uimCfgT1MumIndex 1,2 respecitively
IPD4000 MUM in slot 5 = uimCfgT1MumIndex 1
Mini DSLAM NA = uimCfgT1MumIndex 1
Micro DSLAM NA = uimCfgT1MumIndex 1
Note: when configuring a T1 UIM, the user must enter the
index of the MUM, see above table, that corresponds with the
IP address of the remote SNMP agent.What is uimCfgT1MumIndex?
Identifies which MUM slot hosts the T1 UIM this table row describes, following the same slot-to-index mapping used across the chassis; needed when configuring a T1 UIM against the matching remote agent.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.3.2.1.1 snmpwalk -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::uimCfgT1MumIndex
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.3.2.1.1.1 snmpget -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::uimCfgT1MumIndex.1
Start monitoring Paradyne nTech DSLAMs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NTNTECH-CHASSIS-CONFIGURATION-MIB::uimCfgT1MumIndex OID value, configure state conditions and alerts, and monitor any Paradyne nTech DSLAMs from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.8059 | ntntechRootMIB | NTNTECH-ROOT-MIB |
| 1.3.6.1.4.1.8059.1 | ntntechNamingTree | NTNTECH-ROOT-MIB |
| 1.3.6.1.4.1.8059.1.1 | ntntechChassis | NTNTECH-ROOT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.8059.1.1.1 | ntntechChassisConfigurationMIB | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1 | chsCfgMIBObjects | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1 | chsCfgParameterConfiguration | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1 | prmCfgMultiplexerUplinkModule | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.3 | mumCfgUplinkInterfaceModule | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.3.2 | uimCfgT1Table | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.3.2.1 | uimCfgT1Entry | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.3.2.1.1 | uimCfgT1MumIndex | NTNTECH-CHASSIS-CONFIGURATION-MIB |