NTNTECH-CHASSIS-CONFIGURATION-MIB :: uimCfgT1LineBuildout

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › NTNTECH-CHASSIS-CONFIGURATION-MIB › uimCfgT1LineBuildout

uimCfgT1LineBuildout

Module: NTNTECH-CHASSIS-CONFIGURATION-MIB

OID (symbolic): NTNTECH-CHASSIS-CONFIGURATION-MIB::uimCfgT1LineBuildout

OID (numeric): 1.3.6.1.4.1.8059.1.1.1.1.1.1.3.2.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The line buildout parameter for a T1 UIM.

What is uimCfgT1LineBuildout?

Sets the T1 line buildout (transmit signal attenuation), used to match the cable run length between this DSLAM and the far end so the signal isn't over- or under-driven.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.3.2.1.5
snmpwalk -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::uimCfgT1LineBuildout

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.3.2.1.5.1
snmpget -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::uimCfgT1LineBuildout.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.3.2.1.5.1 i <value>

Start monitoring Paradyne nTech DSLAMs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NTNTECH-CHASSIS-CONFIGURATION-MIB::uimCfgT1LineBuildout OID value, configure state conditions and alerts, and monitor any Paradyne nTech DSLAMs from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8059ntntechRootMIBNTNTECH-ROOT-MIB
1.3.6.1.4.1.8059.1ntntechNamingTreeNTNTECH-ROOT-MIB
1.3.6.1.4.1.8059.1.1ntntechChassisNTNTECH-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8059.1.1.1ntntechChassisConfigurationMIBNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1chsCfgMIBObjectsNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1chsCfgParameterConfigurationNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1prmCfgMultiplexerUplinkModuleNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.3mumCfgUplinkInterfaceModuleNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.3.2uimCfgT1TableNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.3.2.1uimCfgT1EntryNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.3.2.1.5uimCfgT1LineBuildoutNTNTECH-CHASSIS-CONFIGURATION-MIB