NTNTECH-CHASSIS-CONFIGURATION-MIB :: snmpCfgNoticeIpAddress

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › NTNTECH-CHASSIS-CONFIGURATION-MIB › snmpCfgNoticeIpAddress

snmpCfgNoticeIpAddress

Module: NTNTECH-CHASSIS-CONFIGURATION-MIB

OID (symbolic): NTNTECH-CHASSIS-CONFIGURATION-MIB::snmpCfgNoticeIpAddress

OID (numeric): 1.3.6.1.4.1.8059.1.1.1.1.1.1.4.1.1.2

Node type: OBJECT-TYPE

Type: IpAddress

Access: read-write

Description: IP Address of the location or computer to which you would like trap notifications sent. The default value is 0.0.0.0 and it can be modified by the user.

What is snmpCfgNoticeIpAddress?

The IP address of one of up to four management stations that SNMP trap notifications should be sent to; defaults to 0.0.0.0 (unset) until the admin configures a destination.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.4.1.1.2
snmpwalk -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::snmpCfgNoticeIpAddress

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.4.1.1.2.1
snmpget -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::snmpCfgNoticeIpAddress.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.4.1.1.2.1 a <value>

Start monitoring Paradyne nTech DSLAMs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NTNTECH-CHASSIS-CONFIGURATION-MIB::snmpCfgNoticeIpAddress OID value, configure state conditions and alerts, and monitor any Paradyne nTech DSLAMs from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8059ntntechRootMIBNTNTECH-ROOT-MIB
1.3.6.1.4.1.8059.1ntntechNamingTreeNTNTECH-ROOT-MIB
1.3.6.1.4.1.8059.1.1ntntechChassisNTNTECH-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8059.1.1.1ntntechChassisConfigurationMIBNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1chsCfgMIBObjectsNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1chsCfgParameterConfigurationNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1prmCfgMultiplexerUplinkModuleNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.4mumSNMPConfigurationNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.4.1snmpCfgNoticeIpTableNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.4.1.1snmpCfgNoticeIpEntryNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.4.1.1.2snmpCfgNoticeIpAddressNTNTECH-CHASSIS-CONFIGURATION-MIB