All MIBs › NTNTECH-CHASSIS-CONFIGURATION-MIB › snmpCfgNoticeIpAddress
snmpCfgNoticeIpAddress
Module: NTNTECH-CHASSIS-CONFIGURATION-MIB
OID (symbolic): NTNTECH-CHASSIS-CONFIGURATION-MIB::snmpCfgNoticeIpAddress
OID (numeric): 1.3.6.1.4.1.8059.1.1.1.1.1.1.4.1.1.2
Node type: OBJECT-TYPE
Type: IpAddress
Access: read-write
Description: IP Address of the location or computer to which you would like trap notifications sent. The default value is 0.0.0.0 and it can be modified by the user.
What is snmpCfgNoticeIpAddress?
The IP address of one of up to four management stations that SNMP trap notifications should be sent to; defaults to 0.0.0.0 (unset) until the admin configures a destination.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.4.1.1.2 snmpwalk -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::snmpCfgNoticeIpAddress
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.4.1.1.2.1 snmpget -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::snmpCfgNoticeIpAddress.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.4.1.1.2.1 a <value>
Start monitoring Paradyne nTech DSLAMs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NTNTECH-CHASSIS-CONFIGURATION-MIB::snmpCfgNoticeIpAddress OID value, configure state conditions and alerts, and monitor any Paradyne nTech DSLAMs from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.8059 | ntntechRootMIB | NTNTECH-ROOT-MIB |
| 1.3.6.1.4.1.8059.1 | ntntechNamingTree | NTNTECH-ROOT-MIB |
| 1.3.6.1.4.1.8059.1.1 | ntntechChassis | NTNTECH-ROOT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.8059.1.1.1 | ntntechChassisConfigurationMIB | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1 | chsCfgMIBObjects | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1 | chsCfgParameterConfiguration | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1 | prmCfgMultiplexerUplinkModule | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.4 | mumSNMPConfiguration | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.4.1 | snmpCfgNoticeIpTable | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.4.1.1 | snmpCfgNoticeIpEntry | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.4.1.1.2 | snmpCfgNoticeIpAddress | NTNTECH-CHASSIS-CONFIGURATION-MIB |