NTNTECH-CHASSIS-CONFIGURATION-MIB :: mumCfgInterConnection

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › NTNTECH-CHASSIS-CONFIGURATION-MIB › mumCfgInterConnection

mumCfgInterConnection

Module: NTNTECH-CHASSIS-CONFIGURATION-MIB

OID (symbolic): NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgInterConnection

OID (numeric): 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: IPD12000 or IPD4000 DSLAM interconnect configuration provides the system manager the ability to daisy-chain one IP DSLAM to another so that a single router may be used for all DSLAMs in the chain.

What is mumCfgInterConnection?

Selects which uplink (or the management port) is used to daisy-chain this IP DSLAM to the next one in a chain, so a single upstream router can serve every DSLAM in the chain.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.7
snmpwalk -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgInterConnection

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.7.1
snmpget -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgInterConnection.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.7.1 i <value>

Start monitoring Paradyne nTech DSLAMs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgInterConnection OID value, configure state conditions and alerts, and monitor any Paradyne nTech DSLAMs from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8059ntntechRootMIBNTNTECH-ROOT-MIB
1.3.6.1.4.1.8059.1ntntechNamingTreeNTNTECH-ROOT-MIB
1.3.6.1.4.1.8059.1.1ntntechChassisNTNTECH-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8059.1.1.1ntntechChassisConfigurationMIBNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1chsCfgMIBObjectsNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1chsCfgParameterConfigurationNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1prmCfgMultiplexerUplinkModuleNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.2mumCfgTableNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1mumCfgEntryNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.7mumCfgInterConnectionNTNTECH-CHASSIS-CONFIGURATION-MIB