mumCfgIndex

Module: NTNTECH-CHASSIS-CONFIGURATION-MIB

OID (symbolic): NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgIndex

OID (numeric): 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Translates to the physical slot number that a MUM200-2/2000-2 module 
exists within a chassis. The Mini/Micro DSLAMs' physical location is
set to 1 by default.  See below,  

 chassis type     physical location(s) translation
 ------------     --------------------------------          
   IPD12000               MUM in slots 13,14 = mumCfgIndex 1,2 respecitively 
   IPD4000                MUM in slot 5      = mumCfgIndex 1 
   Mini DSLAM     NA                             = mumCfgIndex 1
   Micro DSLAM    NA                             = mumCfgIndex 1

What is mumCfgIndex?

Identifies which physical slot a MUM200-2/2000-2 uplink module occupies in the chassis -- slot 13 or 14 map to index 1 or 2 on an IPD12000, while an IPD4000 or Mini/Micro DSLAM (which has only one MUM) always reports index 1.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.1
snmpwalk -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgIndex

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.1.1
snmpget -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgIndex.1

Start monitoring Paradyne nTech DSLAMs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgIndex OID value, configure state conditions and alerts, and monitor any Paradyne nTech DSLAMs from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8059ntntechRootMIBNTNTECH-ROOT-MIB
1.3.6.1.4.1.8059.1ntntechNamingTreeNTNTECH-ROOT-MIB
1.3.6.1.4.1.8059.1.1ntntechChassisNTNTECH-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8059.1.1.1ntntechChassisConfigurationMIBNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1chsCfgMIBObjectsNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1chsCfgParameterConfigurationNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1prmCfgMultiplexerUplinkModuleNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.2mumCfgTableNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1mumCfgEntryNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.1mumCfgIndexNTNTECH-CHASSIS-CONFIGURATION-MIB