All MIBs › NTNTECH-CHASSIS-CONFIGURATION-MIB › mumCfgIndex
mumCfgIndex
Module: NTNTECH-CHASSIS-CONFIGURATION-MIB
OID (symbolic): NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgIndex
OID (numeric): 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Translates to the physical slot number that a MUM200-2/2000-2 module exists within a chassis. The Mini/Micro DSLAMs' physical location is set to 1 by default. See below, chassis type physical location(s) translation ------------ -------------------------------- IPD12000 MUM in slots 13,14 = mumCfgIndex 1,2 respecitively IPD4000 MUM in slot 5 = mumCfgIndex 1 Mini DSLAM NA = mumCfgIndex 1 Micro DSLAM NA = mumCfgIndex 1
What is mumCfgIndex?
Identifies which physical slot a MUM200-2/2000-2 uplink module occupies in the chassis -- slot 13 or 14 map to index 1 or 2 on an IPD12000, while an IPD4000 or Mini/Micro DSLAM (which has only one MUM) always reports index 1.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.1 snmpwalk -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgIndex
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.1.1 snmpget -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgIndex.1
Start monitoring Paradyne nTech DSLAMs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgIndex OID value, configure state conditions and alerts, and monitor any Paradyne nTech DSLAMs from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.8059 | ntntechRootMIB | NTNTECH-ROOT-MIB |
| 1.3.6.1.4.1.8059.1 | ntntechNamingTree | NTNTECH-ROOT-MIB |
| 1.3.6.1.4.1.8059.1.1 | ntntechChassis | NTNTECH-ROOT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.8059.1.1.1 | ntntechChassisConfigurationMIB | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1 | chsCfgMIBObjects | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1 | chsCfgParameterConfiguration | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1 | prmCfgMultiplexerUplinkModule | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.2 | mumCfgTable | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1 | mumCfgEntry | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.1 | mumCfgIndex | NTNTECH-CHASSIS-CONFIGURATION-MIB |