NTNTECH-CHASSIS-CONFIGURATION-MIB :: mumCfgInbandMgmt

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › NTNTECH-CHASSIS-CONFIGURATION-MIB › mumCfgInbandMgmt

mumCfgInbandMgmt

Module: NTNTECH-CHASSIS-CONFIGURATION-MIB

OID (symbolic): NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgInbandMgmt

OID (numeric): 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Inband management feature, when enabled [ON(1)], allows access to the DSLAM via the network against an assigned IP address, subnet mask, and default gateway.

What is mumCfgInbandMgmt?

Enables or disables inband management, which lets an admin reach the DSLAM over the regular data network using its configured IP/mask/gateway instead of only via the dedicated management port.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.5
snmpwalk -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgInbandMgmt

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.5.1
snmpget -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgInbandMgmt.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.5.1 i <value>

Start monitoring Paradyne nTech DSLAMs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgInbandMgmt OID value, configure state conditions and alerts, and monitor any Paradyne nTech DSLAMs from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8059ntntechRootMIBNTNTECH-ROOT-MIB
1.3.6.1.4.1.8059.1ntntechNamingTreeNTNTECH-ROOT-MIB
1.3.6.1.4.1.8059.1.1ntntechChassisNTNTECH-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8059.1.1.1ntntechChassisConfigurationMIBNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1chsCfgMIBObjectsNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1chsCfgParameterConfigurationNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1prmCfgMultiplexerUplinkModuleNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.2mumCfgTableNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1mumCfgEntryNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.5mumCfgInbandMgmtNTNTECH-CHASSIS-CONFIGURATION-MIB