All MIBs › NTNTECH-CHASSIS-CONFIGURATION-MIB › mumCfgInbandMgmt
mumCfgInbandMgmt
Module: NTNTECH-CHASSIS-CONFIGURATION-MIB
OID (symbolic): NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgInbandMgmt
OID (numeric): 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Inband management feature, when enabled [ON(1)], allows access to the DSLAM via the network against an assigned IP address, subnet mask, and default gateway.
What is mumCfgInbandMgmt?
Enables or disables inband management, which lets an admin reach the DSLAM over the regular data network using its configured IP/mask/gateway instead of only via the dedicated management port.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.5 snmpwalk -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgInbandMgmt
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.5.1 snmpget -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgInbandMgmt.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.5.1 i <value>
Start monitoring Paradyne nTech DSLAMs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgInbandMgmt OID value, configure state conditions and alerts, and monitor any Paradyne nTech DSLAMs from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.8059 | ntntechRootMIB | NTNTECH-ROOT-MIB |
| 1.3.6.1.4.1.8059.1 | ntntechNamingTree | NTNTECH-ROOT-MIB |
| 1.3.6.1.4.1.8059.1.1 | ntntechChassis | NTNTECH-ROOT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.8059.1.1.1 | ntntechChassisConfigurationMIB | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1 | chsCfgMIBObjects | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1 | chsCfgParameterConfiguration | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1 | prmCfgMultiplexerUplinkModule | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.2 | mumCfgTable | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1 | mumCfgEntry | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.5 | mumCfgInbandMgmt | NTNTECH-CHASSIS-CONFIGURATION-MIB |