All MIBs › NTNTECH-CHASSIS-CONFIGURATION-MIB › mumCfgInbandMGMTVlanID
mumCfgInbandMGMTVlanID
Module: NTNTECH-CHASSIS-CONFIGURATION-MIB
OID (symbolic): NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgInbandMGMTVlanID
OID (numeric): 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: The IP DSLAM supports 802.1Q Virtual LANs (VLANs). This parameter configuration applies to the inband management traffic only.
It does not apply to out of band traffic received from the MGMT port.
Note: for the case where the chassis type is an IPD12000 loaded with two MUMs, the setting of this parameter will affect both.
What is mumCfgInbandMGMTVlanID?
The 802.1Q VLAN ID used for inband management traffic only (out-of-band traffic on the MGMT port is unaffected); on an IPD12000 with two MUM modules, setting this value affects both of them.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.6 snmpwalk -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgInbandMGMTVlanID
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.6.1 snmpget -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgInbandMGMTVlanID.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.6.1 i <value>
Start monitoring Paradyne nTech DSLAMs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NTNTECH-CHASSIS-CONFIGURATION-MIB::mumCfgInbandMGMTVlanID OID value, configure state conditions and alerts, and monitor any Paradyne nTech DSLAMs from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.8059 | ntntechRootMIB | NTNTECH-ROOT-MIB |
| 1.3.6.1.4.1.8059.1 | ntntechNamingTree | NTNTECH-ROOT-MIB |
| 1.3.6.1.4.1.8059.1.1 | ntntechChassis | NTNTECH-ROOT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.8059.1.1.1 | ntntechChassisConfigurationMIB | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1 | chsCfgMIBObjects | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1 | chsCfgParameterConfiguration | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1 | prmCfgMultiplexerUplinkModule | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.2 | mumCfgTable | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1 | mumCfgEntry | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.2.1.6 | mumCfgInbandMGMTVlanID | NTNTECH-CHASSIS-CONFIGURATION-MIB |