NTNTECH-CHASSIS-CONFIGURATION-MIB :: mgmtPortCfgType

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › NTNTECH-CHASSIS-CONFIGURATION-MIB › mgmtPortCfgType

mgmtPortCfgType

Module: NTNTECH-CHASSIS-CONFIGURATION-MIB

OID (symbolic): NTNTECH-CHASSIS-CONFIGURATION-MIB::mgmtPortCfgType

OID (numeric): 1.3.6.1.4.1.8059.1.1.1.1.1.1.7.1.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Set the management port type as follows. By setting this port to mgmt(1), it will operate as a non-bridge mode connection. Setting it to uplink(2), this port will operate like an uplink interface module, i.e. a bridge mode connection.

Note: this applies to the AuD8000-12 micro DSLAM only.

What is mgmtPortCfgType?

On the AuD8000-12 micro DSLAM only, sets whether the management port behaves as a plain non-bridged management connection (mgmt) or as a bridged uplink interface (uplink).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.7.1.1.4
snmpwalk -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::mgmtPortCfgType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.7.1.1.4.1
snmpget -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::mgmtPortCfgType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.7.1.1.4.1 i <value>

Start monitoring Paradyne nTech DSLAMs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NTNTECH-CHASSIS-CONFIGURATION-MIB::mgmtPortCfgType OID value, configure state conditions and alerts, and monitor any Paradyne nTech DSLAMs from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8059ntntechRootMIBNTNTECH-ROOT-MIB
1.3.6.1.4.1.8059.1ntntechNamingTreeNTNTECH-ROOT-MIB
1.3.6.1.4.1.8059.1.1ntntechChassisNTNTECH-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8059.1.1.1ntntechChassisConfigurationMIBNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1chsCfgMIBObjectsNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1chsCfgParameterConfigurationNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1prmCfgMultiplexerUplinkModuleNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.7mumCfgManagementPortNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.7.1mgmtPortCfgTableNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.7.1.1mgmtPortCfgEntryNTNTECH-CHASSIS-CONFIGURATION-MIB