All MIBs › NTNTECH-CHASSIS-CONFIGURATION-MIB › advCfgMumIndex
advCfgMumIndex
Module: NTNTECH-CHASSIS-CONFIGURATION-MIB
OID (symbolic): NTNTECH-CHASSIS-CONFIGURATION-MIB::advCfgMumIndex
OID (numeric): 1.3.6.1.4.1.8059.1.1.1.1.1.1.6.1.1.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Translates to the physical slot number that a MUM200-2/2000-2 module
exists within a chassis. The Mini/Micro DSLAMs' physical location is
set to 1 by default. See below,
chassis type physical location(s) translation
------------ --------------------------------
IPD12000 MUM in slots 13,14 = uimCfgE1MumIndex 1,2 respecitively
IPD4000 MUM in slot 5 = uimCfgE1MumIndex 1
Mini DSLAM NA = uimCfgE1MumIndex 1
Micro DSLAM NA = uimCfgE1MumIndex 1
Note: when configuring an Advanced Configuration parameter, the user
must enter the index of the MUM, see above table, that corresponds
with the IP address of the remote SNMP agent.What is advCfgMumIndex?
Identifies which MUM slot this advanced-configuration table row applies to, following the chassis's standard slot-to-index mapping; needed when configuring an advanced parameter against the matching remote agent.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.6.1.1.1 snmpwalk -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::advCfgMumIndex
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.6.1.1.1.1 snmpget -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::advCfgMumIndex.1
Start monitoring Paradyne nTech DSLAMs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NTNTECH-CHASSIS-CONFIGURATION-MIB::advCfgMumIndex OID value, configure state conditions and alerts, and monitor any Paradyne nTech DSLAMs from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.8059 | ntntechRootMIB | NTNTECH-ROOT-MIB |
| 1.3.6.1.4.1.8059.1 | ntntechNamingTree | NTNTECH-ROOT-MIB |
| 1.3.6.1.4.1.8059.1.1 | ntntechChassis | NTNTECH-ROOT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.8059.1.1.1 | ntntechChassisConfigurationMIB | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1 | chsCfgMIBObjects | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1 | chsCfgParameterConfiguration | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1 | prmCfgMultiplexerUplinkModule | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.6 | mumCfgAdvanced | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.6.1 | advCfgTable | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.6.1.1 | advCfgEntry | NTNTECH-CHASSIS-CONFIGURATION-MIB |
| 1.3.6.1.4.1.8059.1.1.1.1.1.1.6.1.1.1 | advCfgMumIndex | NTNTECH-CHASSIS-CONFIGURATION-MIB |