Type: INTEGER

Access: read-only

Description: Translates to the physical slot number that a MUM200-2/2000-2 module 
exists within a chassis. The Mini/Micro DSLAMs' physical location is
set to 1 by default.  See below,  

 chassis type     physical location(s) translation
 ------------     --------------------------------          
   IPD12000       MUM in slots 13,14 = uimCfgE1MumIndex 1,2 respecitively 
   IPD4000        MUM in slot 5      = uimCfgE1MumIndex 1 
   Mini DSLAM     NA                             = uimCfgE1MumIndex 1
   Micro DSLAM    NA                             = uimCfgE1MumIndex 1
   
   Note: when configuring an Advanced Configuration parameter, the user
         must enter the index of the MUM, see above table, that corresponds
         with the IP address of the remote SNMP agent.

What is advCfgMumIndex?

Identifies which MUM slot this advanced-configuration table row applies to, following the chassis's standard slot-to-index mapping; needed when configuring an advanced parameter against the matching remote agent.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.6.1.1.1
snmpwalk -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::advCfgMumIndex

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8059.1.1.1.1.1.1.6.1.1.1.1
snmpget -v2c -c public <target> NTNTECH-CHASSIS-CONFIGURATION-MIB::advCfgMumIndex.1

Start monitoring Paradyne nTech DSLAMs with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NTNTECH-CHASSIS-CONFIGURATION-MIB::advCfgMumIndex OID value, configure state conditions and alerts, and monitor any Paradyne nTech DSLAMs from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8059ntntechRootMIBNTNTECH-ROOT-MIB
1.3.6.1.4.1.8059.1ntntechNamingTreeNTNTECH-ROOT-MIB
1.3.6.1.4.1.8059.1.1ntntechChassisNTNTECH-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8059.1.1.1ntntechChassisConfigurationMIBNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1chsCfgMIBObjectsNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1chsCfgParameterConfigurationNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1prmCfgMultiplexerUplinkModuleNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.6mumCfgAdvancedNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.6.1advCfgTableNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.6.1.1advCfgEntryNTNTECH-CHASSIS-CONFIGURATION-MIB
1.3.6.1.4.1.8059.1.1.1.1.1.1.6.1.1.1advCfgMumIndexNTNTECH-CHASSIS-CONFIGURATION-MIB