NSCRTV-ROOT :: oaDCPowerVoltage

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsNSCRTV-ROOToaDCPowerVoltage

oaDCPowerVoltage

Module: NSCRTV-ROOT

OID (symbolic): NSCRTV-ROOT::oaDCPowerVoltage

OID (numeric): 1.3.6.1.4.1.17409.1.11.7.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Supply voltage, the unit is 0.1 V. This attribute MIB objects require an entry in the register.

What is oaDCPowerVoltage?

The output voltage of this DC power supply, in units of 0.1 V, over a signed range. Admins monitor this to catch a supply that's drifting out of its expected voltage band before it causes downstream equipment problems.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.17409.1.11.7.1.2
snmpwalk -v2c -c public <target> NSCRTV-ROOT::oaDCPowerVoltage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.17409.1.11.7.1.2.1
snmpget -v2c -c public <target> NSCRTV-ROOT::oaDCPowerVoltage.1

Start monitoring HFC (Hybrid Fiber Coax) cable plant equipment / EMS node (NSCRTV, enterprise OID root) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NSCRTV-ROOT::oaDCPowerVoltage OID value, configure state conditions and alerts, and monitor any HFC (Hybrid Fiber Coax) cable plant equipment / EMS node (NSCRTV, enterprise OID root) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.17409nscrtvRootNSCRTV-EPONEOC-EPON-MIB
1.3.6.1.4.1.17409.1nscrtvHFCemsTreeNSCRTV-EPONEOC-EPON-MIB
Numeric OIDNameModule
1.3.6.1.4.1.17409.1.11oaIdentNSCRTV-ROOT
1.3.6.1.4.1.17409.1.11.7oaDCPowerTableNSCRTV-ROOT
1.3.6.1.4.1.17409.1.11.7.1oaDCPowerEntryNSCRTV-ROOT
1.3.6.1.4.1.17409.1.11.7.1.2oaDCPowerVoltageNSCRTV-ROOT