All MIBs › NSCRTV-ROOT › oaDCPowerVoltage
oaDCPowerVoltage
Module: NSCRTV-ROOT
OID (symbolic): NSCRTV-ROOT::oaDCPowerVoltage
OID (numeric): 1.3.6.1.4.1.17409.1.11.7.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Supply voltage, the unit is 0.1 V. This attribute MIB objects require an entry in the register.
What is oaDCPowerVoltage?
The output voltage of this DC power supply, in units of 0.1 V, over a signed range. Admins monitor this to catch a supply that's drifting out of its expected voltage band before it causes downstream equipment problems.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.17409.1.11.7.1.2 snmpwalk -v2c -c public <target> NSCRTV-ROOT::oaDCPowerVoltage
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.17409.1.11.7.1.2.1 snmpget -v2c -c public <target> NSCRTV-ROOT::oaDCPowerVoltage.1
Start monitoring HFC (Hybrid Fiber Coax) cable plant equipment / EMS node (NSCRTV, enterprise OID root) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NSCRTV-ROOT::oaDCPowerVoltage OID value, configure state conditions and alerts, and monitor any HFC (Hybrid Fiber Coax) cable plant equipment / EMS node (NSCRTV, enterprise OID root) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.17409 | nscrtvRoot | NSCRTV-EPONEOC-EPON-MIB |
| 1.3.6.1.4.1.17409.1 | nscrtvHFCemsTree | NSCRTV-EPONEOC-EPON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.17409.1.11 | oaIdent | NSCRTV-ROOT |
| 1.3.6.1.4.1.17409.1.11.7 | oaDCPowerTable | NSCRTV-ROOT |
| 1.3.6.1.4.1.17409.1.11.7.1 | oaDCPowerEntry | NSCRTV-ROOT |
| 1.3.6.1.4.1.17409.1.11.7.1.2 | oaDCPowerVoltage | NSCRTV-ROOT |