All MIBs › NSCRTV-ROOT › commonProvisionedReturnPowerLevel
commonProvisionedReturnPowerLevel
Module: NSCRTV-ROOT
OID (symbolic): NSCRTV-ROOT::commonProvisionedReturnPowerLevel
OID (numeric): 1.3.6.1.4.1.17409.1.3.2.2.3
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Upstream channel power levels and units for dBuV. When the internal use of this value will be rounded to the nearest support value. Reading return to this subject when the actual value rather than rounding value. The value of this object should be stored in non-volatile memory.
What is commonProvisionedReturnPowerLevel?
The provisioned upstream transmit power level in dBµV; internally the device rounds this to its nearest supported step, but reads back the true set value rather than the rounded one. Admins tune this to keep the upstream signal within the head-end's acceptable receive range, and it's stored in non-volatile memory.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.17409.1.3.2.2.3 snmpwalk -v2c -c public <target> NSCRTV-ROOT::commonProvisionedReturnPowerLevel
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.17409.1.3.2.2.3.1 snmpget -v2c -c public <target> NSCRTV-ROOT::commonProvisionedReturnPowerLevel.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.17409.1.3.2.2.3.1 i <value>
Start monitoring HFC (Hybrid Fiber Coax) cable plant equipment / EMS node (NSCRTV, enterprise OID root) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NSCRTV-ROOT::commonProvisionedReturnPowerLevel OID value, configure state conditions and alerts, and monitor any HFC (Hybrid Fiber Coax) cable plant equipment / EMS node (NSCRTV, enterprise OID root) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.17409 | nscrtvRoot | NSCRTV-EPONEOC-EPON-MIB |
| 1.3.6.1.4.1.17409.1 | nscrtvHFCemsTree | NSCRTV-EPONEOC-EPON-MIB |
| 1.3.6.1.4.1.17409.1.3.2 | commonAdminUseRf | NSCRTV-HFCEMS-COMMON-MIB |
| 1.3.6.1.4.1.17409.1.3.2.2 | commonRfGroup | NSCRTV-HFCEMS-COMMON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.17409.1.3 | commonIdent | NSCRTV-ROOT |
| 1.3.6.1.4.1.17409.1.3.2.2.3 | commonProvisionedReturnPowerLevel | NSCRTV-ROOT |