All MIBs › NSCRTV-ROOT › commonCheckCode
commonCheckCode
Module: NSCRTV-ROOT
OID (symbolic): NSCRTV-ROOT::commonCheckCode
OID (numeric): 1.3.6.1.4.1.17409.1.3.1.10
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This target for the detection transponder code configuration of the report. The calculation includes detection code transponder (including management equipment) and the physical configuration parameters stored in non-volatile memory of all the parameters. The detection algorithm calculated by the vendor code provisions. The object should be kept in the value of non-volatile memory, the response thinks highly activated, will be recalculated and re-testing code and the value prior to the commencement of comparison to determine whether or should haveһ��hfcColdStart hfcWarmStart traps. When write this object (SetRequest), the detection code will be recalculated and fill the SetRequest in response to the GetResponse. At this time, will not produce or hfcWarmStart traps hfcColdStart.
What is commonCheckCode?
A vendor-computed checksum over the device's stored configuration parameters, recalculated at boot and compared to the saved value to decide whether to send a hfcColdStart or hfcWarmStart trap; writing to this object forces an immediate recalculation without generating either trap. Admins mainly encounter it indirectly, as the mechanism behind cold-start vs warm-start trap behavior after a config change.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.17409.1.3.1.10 snmpwalk -v2c -c public <target> NSCRTV-ROOT::commonCheckCode
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.17409.1.3.1.10.1 snmpget -v2c -c public <target> NSCRTV-ROOT::commonCheckCode.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.17409.1.3.1.10.1 i <value>
Start monitoring HFC (Hybrid Fiber Coax) cable plant equipment / EMS node (NSCRTV, enterprise OID root) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NSCRTV-ROOT::commonCheckCode OID value, configure state conditions and alerts, and monitor any HFC (Hybrid Fiber Coax) cable plant equipment / EMS node (NSCRTV, enterprise OID root) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.17409 | nscrtvRoot | NSCRTV-EPONEOC-EPON-MIB |
| 1.3.6.1.4.1.17409.1 | nscrtvHFCemsTree | NSCRTV-EPONEOC-EPON-MIB |
| 1.3.6.1.4.1.17409.1.3.1 | commonAdminGroup | NSCRTV-HFCEMS-COMMON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.17409.1.3 | commonIdent | NSCRTV-ROOT |
| 1.3.6.1.4.1.17409.1.3.1.10 | commonCheckCode | NSCRTV-ROOT |