Node type: OBJECT-TYPE
Type: DateAndTime
Access: read-only
Description: The time stamp when alarm occurs, where the alarm is duplicated with existed active alarm entry, and it was the latest one.
What is activeAlarmLastOccurTime?
Timestamp of the most recent occurrence of this same alarm condition, updated each time a duplicate of an already-active alarm is detected rather than creating a new row.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.17409.2.2.11.2.1.1.7 snmpwalk -v2c -c public <target> NSCRTV-EPON-ALARM-MGM-MIB::activeAlarmLastOccurTime
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.17409.2.2.11.2.1.1.7.1 snmpget -v2c -c public <target> NSCRTV-EPON-ALARM-MGM-MIB::activeAlarmLastOccurTime.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> activeAlarmLastOccurTime.1
Start monitoring NSCRTV EPON Optical Line Terminal (cable TV/broadband access, alarm management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NSCRTV-EPON-ALARM-MGM-MIB::activeAlarmLastOccurTime OID value, configure state conditions and alerts, and monitor any NSCRTV EPON Optical Line Terminal (cable TV/broadband access, alarm management) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.17409 | nscrtvRoot | NSCRTV-EPONEOC-EPON-MIB |
| 1.3.6.1.4.1.17409.2 | nscrtvEponEocTree | NSCRTV-EPONEOC-EPON-MIB |
| 1.3.6.1.4.1.17409.2.2 | alarmsIdent | NSCRTV-EPONEOC-EPON-MIB |
| 1.3.6.1.4.1.17409.2.2.11 | eponAlarmTree | NSCRTV-EPONEOC-EPON-MIB |
| 1.3.6.1.4.1.17409.2.2.11.2 | eponAlarmObjGroup | NSCRTV-EPONEOC-EPON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.17409.2.2.11.2.1 | activeAlarmTable | NSCRTV-EPON-ALARM-MGM-MIB |
| 1.3.6.1.4.1.17409.2.2.11.2.1.1 | activeAlarmEntry | NSCRTV-EPON-ALARM-MGM-MIB |
| 1.3.6.1.4.1.17409.2.2.11.2.1.1.7 | activeAlarmLastOccurTime | NSCRTV-EPON-ALARM-MGM-MIB |