NSCRTV-EPON-ALARM-MGM-MIB :: activeAlarmTable

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › NSCRTV-EPON-ALARM-MGM-MIB › activeAlarmTable

activeAlarmTable

Module: NSCRTV-EPON-ALARM-MGM-MIB

OID (symbolic): NSCRTV-EPON-ALARM-MGM-MIB::activeAlarmTable

OID (numeric): 1.3.6.1.4.1.17409.2.2.11.2.1

Node type: OBJECT-TYPE

Access: not-accessible

Description: Active alarm table
        
        The device shall maintain this table, to maintain all outstanding 
        (not cleared) alarms generated by the device, including:
        1. Not hit device local alarm filter. That means had been reported to
           trap receiver (NMS or EMS)
        2. Hit local alarm filter. That means not trap is reported to trap receiver
           for the alarm.
        
        The device shall maintain two numbers:
        1. Alarm sequence number: As described in eponTrapSequenceNumber, it is initially
           set to 1 when device restarts, increases per trap reported to trap receiver,
           and rollover to 1 once it reaches the maximum value. 
           From NMS's view, traps received from a nodes will be consecutive, by identifying 
           the alarm sequence number carried in alarm trap. If breaks, means some trap 
           may be lost, since packet loss between NMS and NE. 
        2. Alarm raising number: This is maintained by NE internally and does not intend for
           being acknowledged by external manage system. It is designed to uniquely indentify
           each alarm raised by NE, excluding duplicates. Once one alarm raised, despite 
           whether it is hit by alarm filter, NE shall assign a raising number to it. So, it
           major functionality is to uniquely identify alarms hit NE local alarm filter, since 
           this kindly alarm will not be reported to NMS, and hence no alarm sequence number
           is assigned to it.
           It is initially  set to 1 when device restarts, increases per alarm generation (
           excluding duplicates), and rollover to 1 once it reaches the maximum value. 
        
        FUNCTION DESCRIPTION OF ACTIVE ALARM TABLE:         
        ALARM RAISING
        ----------------------        
        1. When NE detects one fault and associates to one kind of alarm, it shall check whether
           there is same alarm in active alarm table, which is indexed by alarm code and alarm
           instance. If hits, it means duplicates, update the corresponding entry of the table.
           Otherwise,
        2. The alarm is not a duplicate. Assign an alarm raising number. Check whether the
 alarm hits local alarm filters. If hits, set alarm sequence number to 0.
           Create an entry into active alarm table. Otherwise,
        3. Assign an alarm sequence number to the alarm. Create an entry into active alarm
 table. Report the alarm trap to all trap receivers.
           
        ALARM CLEARING
        ----------------------        
        1. When NE detects one fault is cleared and associates to one kind of alarm, it shall 
           check whether there is corresponding alarm in active alarm table, which is indexed
by alarm code and alarm instance. If no hit, escape this clear event. Upon a hit,
if the alarm sequence number is 0, move the active alarm entry to history alarm
table and update the corresponding fields. At this case, historyAlarmCorrelationId
and historyAlarmSeqNum will be set to 0.
           Otherwise,
        2. Assign an alarm sequence number to the clear trap. Report the alarm clear trap to 
           all trap receivers. Move the active alarm entry to history alarm table and update 
           the corresponding fields. At this case, activeAlarmSeqNum shall be copied to 
           historyAlarmCorrelationId, and historyAlarmSeqNum shall be set to the new alarm
           sequence number for the clear trap.
        
        ALARM SYNCHRONIZATION BETWEEN NE AND NMS
        ---------------------------------------------        
        1. Once NMS finds the alarm sequence number in reported alarm traps is not continuous,
           it will walk active or history alarm table of the NE for the lost seuqence number.
        

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.17409nscrtvRootNSCRTV-EPONEOC-EPON-MIB
1.3.6.1.4.1.17409.2nscrtvEponEocTreeNSCRTV-EPONEOC-EPON-MIB
1.3.6.1.4.1.17409.2.2alarmsIdentNSCRTV-EPONEOC-EPON-MIB
1.3.6.1.4.1.17409.2.2.11eponAlarmTreeNSCRTV-EPONEOC-EPON-MIB
1.3.6.1.4.1.17409.2.2.11.2eponAlarmObjGroupNSCRTV-EPONEOC-EPON-MIB
Numeric OIDNameModule
1.3.6.1.4.1.17409.2.2.11.2.1activeAlarmTableNSCRTV-EPON-ALARM-MGM-MIB