All MIBs › NSCRTV-EPON-ALARM-MGM-MIB › activeAlarmConfirm
activeAlarmConfirm
Module: NSCRTV-EPON-ALARM-MGM-MIB
OID (symbolic): NSCRTV-EPON-ALARM-MGM-MIB::activeAlarmConfirm
OID (numeric): 1.3.6.1.4.1.17409.2.2.11.2.1.1.9
Node type: OBJECT-TYPE
Type: TruthValue
Access: read-write
Description: �澯ȷ�� Node shall not clear an active alarm, upon the confirmation of the active alarm, but just mark an acknowledged status.
An alarm will only be cleared once the clear condition hits.
What is activeAlarmConfirm?
Set to true to acknowledge this active alarm; acknowledging only marks it as confirmed and does not clear it — the alarm is only removed from the active table once its underlying clear condition is actually detected.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.17409.2.2.11.2.1.1.9 snmpwalk -v2c -c public <target> NSCRTV-EPON-ALARM-MGM-MIB::activeAlarmConfirm
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.17409.2.2.11.2.1.1.9.1 snmpget -v2c -c public <target> NSCRTV-EPON-ALARM-MGM-MIB::activeAlarmConfirm.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.17409.2.2.11.2.1.1.9.1 s <value>
Start monitoring NSCRTV EPON Optical Line Terminal (cable TV/broadband access, alarm management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NSCRTV-EPON-ALARM-MGM-MIB::activeAlarmConfirm OID value, configure state conditions and alerts, and monitor any NSCRTV EPON Optical Line Terminal (cable TV/broadband access, alarm management) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.17409 | nscrtvRoot | NSCRTV-EPONEOC-EPON-MIB |
| 1.3.6.1.4.1.17409.2 | nscrtvEponEocTree | NSCRTV-EPONEOC-EPON-MIB |
| 1.3.6.1.4.1.17409.2.2 | alarmsIdent | NSCRTV-EPONEOC-EPON-MIB |
| 1.3.6.1.4.1.17409.2.2.11 | eponAlarmTree | NSCRTV-EPONEOC-EPON-MIB |
| 1.3.6.1.4.1.17409.2.2.11.2 | eponAlarmObjGroup | NSCRTV-EPONEOC-EPON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.17409.2.2.11.2.1 | activeAlarmTable | NSCRTV-EPON-ALARM-MGM-MIB |
| 1.3.6.1.4.1.17409.2.2.11.2.1.1 | activeAlarmEntry | NSCRTV-EPON-ALARM-MGM-MIB |
| 1.3.6.1.4.1.17409.2.2.11.2.1.1.9 | activeAlarmConfirm | NSCRTV-EPON-ALARM-MGM-MIB |