NOKIA-ENHANCED-SNMP-SOLUTION-SUITE-PM-IRP :: noiMeasurementScheduleFileDirectory

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › NOKIA-ENHANCED-SNMP-SOLUTION-SUITE-PM-IRP › noiMeasurementScheduleFileDirectory

noiMeasurementScheduleFileDirectory

Module: NOKIA-ENHANCED-SNMP-SOLUTION-SUITE-PM-IRP

OID (symbolic): NOKIA-ENHANCED-SNMP-SOLUTION-SUITE-PM-IRP::noiMeasurementScheduleFileDirectory

OID (numeric): 1.3.6.1.4.1.94.7.3.2.4

Node type: OBJECT-TYPE

Type: NoiMeasurementFileDirectory

Access: read-write

Description: Contains the directory where the measurement schedule file is stored within the agent. The manager polls the value before downloading the measurement file. NetAct does not modify this object, but it shall be the responsibility of the agent to set the appropriate values. From a NetAct perspective, this object is treated as it would be specified as read-only. The object has been declared as read-write, to allow for instance configuring this value by an EM.

What is noiMeasurementScheduleFileDirectory?

Gives the directory path on the agent where the measurement schedule file is stored, typed as NoiMeasurementFileDirectory. NetAct polls this object before attempting to download the schedule file, so it always fetches from the agent's current location rather than a hardcoded path. For example, a value of "/pm/schedule/" tells NetAct exactly where on the agent's filesystem to retrieve the measurement schedule.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.94.7.3.2.4
snmpwalk -v2c -c public <target> NOKIA-ENHANCED-SNMP-SOLUTION-SUITE-PM-IRP::noiMeasurementScheduleFileDirectory

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.94.7.3.2.4.1
snmpget -v2c -c public <target> NOKIA-ENHANCED-SNMP-SOLUTION-SUITE-PM-IRP::noiMeasurementScheduleFileDirectory.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.94.7.3.2.4.1 s <value>

Start monitoring Nokia radio access or core network element (PM data to NetAct) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NOKIA-ENHANCED-SNMP-SOLUTION-SUITE-PM-IRP::noiMeasurementScheduleFileDirectory OID value, configure state conditions and alerts, and monitor any Nokia radio access or core network element (PM data to NetAct) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.94nokiaNOKIA-AZC-REGISTRATION-MIB
1.3.6.1.4.1.94.7nokiaSnmpInterfaceNOKIA-OID-REGISTRATION-MIB
1.3.6.1.4.1.94.7.3noiPerformanceManagementNOKIA-NE3S-REGISTRATION-MIB
1.3.6.1.4.1.94.7.3.2noiPmVariableNOKIA-NE3S-REGISTRATION-MIB
Numeric OIDNameModule
1.3.6.1.4.1.94.7.3.2.4noiMeasurementScheduleFileDirectoryNOKIA-ENHANCED-SNMP-SOLUTION-SUITE-PM-IRP