All MIBs › NMS-POWER-EXT-MIB › powerShelfNum
powerShelfNum
Module: NMS-POWER-EXT-MIB
OID (symbolic): NMS-POWER-EXT-MIB::powerShelfNum
OID (numeric): 1.3.6.1.4.1.11606.10.9.251.4.1.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Powerdevice belong to which shelf.
What is powerShelfNum?
This read-write INTEGER (a(1)/b(2)) identifies which shelf a power device belongs to. Admins set or reference this to know which physical shelf, in a dual-shelf chassis, a given power device entry corresponds to. For example, a value of b(2) identifies the device as belonging to the second shelf.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11606.10.9.251.4.1.5 snmpwalk -v2c -c public <target> NMS-POWER-EXT-MIB::powerShelfNum
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11606.10.9.251.4.1.5.1 snmpget -v2c -c public <target> NMS-POWER-EXT-MIB::powerShelfNum.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.11606.10.9.251.4.1.5.1 i <value>
Start monitoring nms Co., Ltd. switch/router with redundant power supplies (vendor unidentified) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NMS-POWER-EXT-MIB::powerShelfNum OID value, configure state conditions and alerts, and monitor any nms Co., Ltd. switch/router with redundant power supplies (vendor unidentified) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11606 | pbn | PBN-ROOT |
| 1.3.6.1.4.1.11606.10 | nms | NMS-SMI |
| 1.3.6.1.4.1.11606.10.9 | nmsMgmt | NMS-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11606.10.9.251 | powerExt | NMS-POWER-EXT-MIB |
| 1.3.6.1.4.1.11606.10.9.251.4 | powerDeviceTable | NMS-POWER-EXT-MIB |
| 1.3.6.1.4.1.11606.10.9.251.4.1 | powerDeviceTableEntry | NMS-POWER-EXT-MIB |
| 1.3.6.1.4.1.11606.10.9.251.4.1.5 | powerShelfNum | NMS-POWER-EXT-MIB |