All MIBs › NMS-EPON-ONU-SERIAL-PORT › onuSerialPortDataReadInterval
onuSerialPortDataReadInterval
Module: NMS-EPON-ONU-SERIAL-PORT
OID (symbolic): NMS-EPON-ONU-SERIAL-PORT::onuSerialPortDataReadInterval
OID (numeric): 1.3.6.1.4.1.11606.10.101.27.1.1.9
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: ONU serial port buffer data read interval. Unit is mili-second, and default value is 100 ms.
What is onuSerialPortDataReadInterval?
This object sets, in milliseconds, how often the ONU reads buffered serial data before forwarding it, ranging from 10 to 100000 ms, with a default of 100 ms. Admins tune this to balance latency against efficiency: a shorter interval sends data more promptly but in smaller chunks, a longer one batches more data per transmission. Lowering this from the 100 ms default to 20 ms would reduce latency for a time-sensitive serial application like SCADA polling.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11606.10.101.27.1.1.9 snmpwalk -v2c -c public <target> NMS-EPON-ONU-SERIAL-PORT::onuSerialPortDataReadInterval
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11606.10.101.27.1.1.9.1 snmpget -v2c -c public <target> NMS-EPON-ONU-SERIAL-PORT::onuSerialPortDataReadInterval.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.11606.10.101.27.1.1.9.1 i <value>
Start monitoring NMS Communications EPON ONU (serial console port) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NMS-EPON-ONU-SERIAL-PORT::onuSerialPortDataReadInterval OID value, configure state conditions and alerts, and monitor any NMS Communications EPON ONU (serial console port) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11606 | pbn | PBN-ROOT |
| 1.3.6.1.4.1.11606.10 | nms | NMS-SMI |
| 1.3.6.1.4.1.11606.10.101 | nmsEPONGroup | NMS-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11606.10.101.27 | nmsEponOnuSerialPort | NMS-EPON-ONU-SERIAL-PORT |
| 1.3.6.1.4.1.11606.10.101.27.1 | nmsEponOnuSerialPortTable | NMS-EPON-ONU-SERIAL-PORT |
| 1.3.6.1.4.1.11606.10.101.27.1.1 | nmsEponOnuSerialPortEntry | NMS-EPON-ONU-SERIAL-PORT |
| 1.3.6.1.4.1.11606.10.101.27.1.1.9 | onuSerialPortDataReadInterval | NMS-EPON-ONU-SERIAL-PORT |