All MIBs › NBS-SIGLANE-MIB › nbsSigLaneLaneTxPowerLevel
nbsSigLaneLaneTxPowerLevel
Module: NBS-SIGLANE-MIB
OID (symbolic): NBS-SIGLANE-MIB::nbsSigLaneLaneTxPowerLevel
OID (numeric): 1.3.6.1.4.1.629.236.20.1.1.20
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: This object indicates the status of this lane's measured received power, reported in nbsSigLaneLaneTxPower:
notSupported(1), if (nbsSigLaneLaneTxPower = 0x80000000);
lowAlarm(2), if nbsSigLaneLaneTxPower < nbsSigLanePortTxPowerVendorMin;
lowWarning(3), if nbsSigLaneLaneTxPower > nbsSigLanePortTxPowerVendorMin and nbsSigLaneLaneTxPower < nbsSigLanePortTxPowerUserMin;
ok(4), if nbsSigLaneLaneTxPower is within thresholds;
highWarning(5), if nbsSigLaneLaneTxPower < nbsSigLanePortTxPowerVendorMax and nbsSigLaneLaneTxPower > nbsSigLanePortTxPowerUserMax;
highAlarm(6), if nbsSigLaneLaneTxPower > nbsSigLanePortTxPowerVendorMax
What is nbsSigLaneLaneTxPowerLevel?
This value indicates the alarm/warning status of this lane's transmit power reading, reported in nbsSigLaneLaneTxPower, relative to vendor and user-configured thresholds. Admins monitor it to catch degrading laser output before it causes link errors: lowAlarm or highAlarm mean the power has crossed a vendor-defined limit, while ok means it is within range. For example, a value of lowAlarm(2) on a lane would tell an admin the transmit power has dropped below the vendor minimum, likely signaling a failing laser.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.629.236.20.1.1.20 snmpwalk -v2c -c public <target> NBS-SIGLANE-MIB::nbsSigLaneLaneTxPowerLevel
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.629.236.20.1.1.20.1 snmpget -v2c -c public <target> NBS-SIGLANE-MIB::nbsSigLaneLaneTxPowerLevel.1
Start monitoring NBS WDM/optical transport network element with multi-lane optics (QSFP/CXP/CFP) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NBS-SIGLANE-MIB::nbsSigLaneLaneTxPowerLevel OID value, configure state conditions and alerts, and monitor any NBS WDM/optical transport network element with multi-lane optics (QSFP/CXP/CFP) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.629 | nbase | CORE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.629.236 | nbsSigLaneMib | NBS-SIGLANE-MIB |
| 1.3.6.1.4.1.629.236.20 | nbsSigLaneLaneGrp | NBS-SIGLANE-MIB |
| 1.3.6.1.4.1.629.236.20.1 | nbsSigLaneLaneTable | NBS-SIGLANE-MIB |
| 1.3.6.1.4.1.629.236.20.1.1 | nbsSigLaneLaneEntry | NBS-SIGLANE-MIB |
| 1.3.6.1.4.1.629.236.20.1.1.20 | nbsSigLaneLaneTxPowerLevel | NBS-SIGLANE-MIB |