All MIBs › NBS-SIGCOND-MIB › nbsSigCondVoaPortTxAttenuOper
nbsSigCondVoaPortTxAttenuOper
Module: NBS-SIGCOND-MIB
OID (symbolic): NBS-SIGCOND-MIB::nbsSigCondVoaPortTxAttenuOper
OID (numeric): 1.3.6.1.4.1.629.227.1.2.1.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Attenuation actually being applied before transmitting signal, in millidecibels (mdB). Not supported value: -200000
What is nbsSigCondVoaPortTxAttenuOper?
This read-only counter reports the attenuation, in millidecibels, actually being applied to the transmitted signal on this port right now. An admin checks it against nbsSigCondVoaPortTxAttenuAdmin to verify a transmit power trim has actually taken hold before re-measuring launch power downstream. A steady mismatch between the Admin and Oper values (e.g. Admin 1500 vs. Oper 0) points to a VOA actuator fault on that port that needs a field technician.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.629.227.1.2.1.5 snmpwalk -v2c -c public <target> NBS-SIGCOND-MIB::nbsSigCondVoaPortTxAttenuOper
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.629.227.1.2.1.5.1 snmpget -v2c -c public <target> NBS-SIGCOND-MIB::nbsSigCondVoaPortTxAttenuOper.1
Start monitoring NBase-Xyplex optical transport/DWDM platform (VOA signal conditioning) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NBS-SIGCOND-MIB::nbsSigCondVoaPortTxAttenuOper OID value, configure state conditions and alerts, and monitor any NBase-Xyplex optical transport/DWDM platform (VOA signal conditioning) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.629 | nbase | CORE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.629.227 | nbsSigCondMib | NBS-SIGCOND-MIB |
| 1.3.6.1.4.1.629.227.1 | nbsSigCondVoaPortGrp | NBS-SIGCOND-MIB |
| 1.3.6.1.4.1.629.227.1.2 | nbsSigCondVoaPortTable | NBS-SIGCOND-MIB |
| 1.3.6.1.4.1.629.227.1.2.1 | nbsSigCondVoaPortEntry | NBS-SIGCOND-MIB |
| 1.3.6.1.4.1.629.227.1.2.1.5 | nbsSigCondVoaPortTxAttenuOper | NBS-SIGCOND-MIB |