MSTP-MIB :: swMSTPStpLBDRecoverTime

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsMSTP-MIBswMSTPStpLBDRecoverTime

swMSTPStpLBDRecoverTime

Module: MSTP-MIB

OID (symbolic): MSTP-MIB::swMSTPStpLBDRecoverTime

OID (numeric): 1.3.6.1.4.1.171.12.15.1.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The period of time(in second) on which STP module keeps checking the BPDU loop status, The valid range is 60 to 1000000 . If set this value from 1 to 59 will get 'bad value' return code. The value of zero is a special value which means to disable the auto-recovery mechanism for LBD feature.

What is swMSTPStpLBDRecoverTime?

This read-write value (0, or 60-1000000 seconds) sets how often the STP module checks whether a loop-back condition detected by LBD has cleared so the port can auto-recover; setting 1-59 returns a bad-value error, and 0 disables auto-recovery entirely. Admins set 0 if they want a looped port to stay shut down until manually re-enabled rather than recovering automatically.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.171.12.15.1.10
snmpwalk -v2c -c public <target> MSTP-MIB::swMSTPStpLBDRecoverTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.171.12.15.1.10.1
snmpget -v2c -c public <target> MSTP-MIB::swMSTPStpLBDRecoverTime.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.171.12.15.1.10.1 i <value>

Start monitoring Enterprise/data-center Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MSTP-MIB::swMSTPStpLBDRecoverTime OID value, configure state conditions and alerts, and monitor any Enterprise/data-center Ethernet switches from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.171d_linkDE1500-MIB
1.3.6.1.4.1.171.12dlink_common_mgmtDLINK-ID-REC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.171.12.15swMSTPMIBMSTP-MIB
1.3.6.1.4.1.171.12.15.1swMSTPGblMgmtMSTP-MIB
1.3.6.1.4.1.171.12.15.1.10swMSTPStpLBDRecoverTimeMSTP-MIB