All MIBs › MODULES-MIB › fethPortDataRateMismatches
fethPortDataRateMismatches
Module: MODULES-MIB
OID (symbolic): MODULES-MIB::fethPortDataRateMismatches
OID (numeric): 1.3.6.1.4.1.81.12.6.1.1.1.23
Node type: OBJECT-TYPE
Type: Counter
Access: read-only
Description: This counter is incremented by one for each frame received on this port that meets all of the following conditions: a) the Collision Count Increment state of the partition state diagram (fig 27-8) has not been entered. b) The ActivityDuration is greater than ValidPacketMinTime. c) The frequency (data rate) is detectably mismatched from the local transmit frequency. The exact degree of mismatch is vendor specific and is to be defined by the vendor for conformance testing.
When this event occurs, other counters whose increment conditions were satisfied may or may not also be incremented, at the implementor's discretion. Whether or not the repeater was able to maintain data integrity is beyond the scope of this standard. REFERENCE Reference IEEE Draft Std 802.3u/D4 Rptr Mgt, 30.4.3.1.14, aDataRateMismatches. Reference IETF 100Base-T Repeater MIB, rptr100MonitorPortDataRateMismatches.
What is fethPortDataRateMismatches?
Counts frames received on this port whose signaling rate was detectably mismatched from the port's own local transmit clock, with the exact mismatch threshold left to vendor discretion; it flags a device on the segment running at a slightly different clock rate than expected, a subtle physical-layer problem that can cause intermittent errors.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.81.12.6.1.1.1.23 snmpwalk -v2c -c public <target> MODULES-MIB::fethPortDataRateMismatches
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.81.12.6.1.1.1.23.1 snmpget -v2c -c public <target> MODULES-MIB::fethPortDataRateMismatches.1
Start monitoring Legacy multi-protocol Ethernet/token-ring hub or concentrator chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MODULES-MIB::fethPortDataRateMismatches OID value, configure state conditions and alerts, and monitor any Legacy multi-protocol Ethernet/token-ring hub or concentrator chassis from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.81 | lannet | GEN-MIB |
| 1.3.6.1.4.1.81.12 | eth | LANNET-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.81.12.6 | feth | MODULES-MIB |
| 1.3.6.1.4.1.81.12.6.1 | fethPort | MODULES-MIB |
| 1.3.6.1.4.1.81.12.6.1.1 | fethPortTable | MODULES-MIB |
| 1.3.6.1.4.1.81.12.6.1.1.1 | fethPortEntry | MODULES-MIB |
| 1.3.6.1.4.1.81.12.6.1.1.1.23 | fethPortDataRateMismatches | MODULES-MIB |