All MIBs › MITSUBISHI-UPS-MIB › upsRebootWithDuration
upsRebootWithDuration
Module: MITSUBISHI-UPS-MIB
OID (symbolic): MITSUBISHI-UPS-MIB::upsRebootWithDuration
OID (numeric): 1.3.6.1.4.1.13891.101.8.4
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, upsRebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.
What is upsRebootWithDuration?
Setting this immediately shuts the UPS output or system off for the given number of seconds and then restarts it, useful for scripting a remote power-cycle of the load; reading it back shows seconds remaining in the cycle, or -1 if none is in progress.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.13891.101.8.4 snmpwalk -v2c -c public <target> MITSUBISHI-UPS-MIB::upsRebootWithDuration
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.13891.101.8.4.1 snmpget -v2c -c public <target> MITSUBISHI-UPS-MIB::upsRebootWithDuration.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.13891.101.8.4.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> upsRebootWithDuration.1
Start monitoring Mitsubishi UPS product line with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MITSUBISHI-UPS-MIB::upsRebootWithDuration OID value, configure state conditions and alerts, and monitor any Mitsubishi UPS product line from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.13891 | tag | MITSUBISHI-UPS-MIB |
| 1.3.6.1.4.1.13891.101 | mitsubishiUPS | MITSUBISHI-UPS-MIB |
| 1.3.6.1.4.1.13891.101.8 | upsControl | MITSUBISHI-UPS-MIB |
| 1.3.6.1.4.1.13891.101.8.4 | upsRebootWithDuration | MITSUBISHI-UPS-MIB |