METRO1500-MIB :: metro1500TDMRxSync

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › METRO1500-MIB › metro1500TDMRxSync

metro1500TDMRxSync

Module: METRO1500-MIB

OID (symbolic): METRO1500-MIB::metro1500TDMRxSync

OID (numeric): 1.3.6.1.4.1.2544.1.3.15.1.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Is the input signal synchronized with the corresponding TDM card?

What is metro1500TDMRxSync?

metro1500TDMRxSync reports whether the input signal on this TDM card is synchronized with the card's own clocking. A noSync value points an operator toward a timing mismatch between the incoming TDM signal and this card's configuration.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.3.15.1.1.5
snmpwalk -v2c -c public <target> METRO1500-MIB::metro1500TDMRxSync

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.3.15.1.1.5.1
snmpget -v2c -c public <target> METRO1500-MIB::metro1500TDMRxSync.1

Start monitoring ADVA/vendor Metro1500 access multiplexer with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the METRO1500-MIB::metro1500TDMRxSync OID value, configure state conditions and alerts, and monitor any ADVA/vendor Metro1500 access multiplexer from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.3metro1500METRO1500-MIB
1.3.6.1.4.1.2544.1.3.15metro1500TDMMETRO1500-MIB
1.3.6.1.4.1.2544.1.3.15.1metro1500TDMTableMETRO1500-MIB
1.3.6.1.4.1.2544.1.3.15.1.1metro1500TDMEntryMETRO1500-MIB
1.3.6.1.4.1.2544.1.3.15.1.1.5metro1500TDMRxSyncMETRO1500-MIB