All MIBs › METRO1500-MIB › metro1500PSOn
metro1500PSOn
Module: METRO1500-MIB
OID (symbolic): METRO1500-MIB::metro1500PSOn
OID (numeric): 1.3.6.1.4.1.2544.1.3.1.3.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Is installed Power Supply On or Off
What is metro1500PSOn?
metro1500PSOn reports whether the power supply identified by metro1500PSNumber is currently on or off. An operator monitors this across all installed supplies to catch a failed or unplugged unit before it causes a loss of redundancy.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.3.1.3.1.2 snmpwalk -v2c -c public <target> METRO1500-MIB::metro1500PSOn
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.3.1.3.1.2.1 snmpget -v2c -c public <target> METRO1500-MIB::metro1500PSOn.1
Start monitoring ADVA/vendor Metro1500 access multiplexer with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the METRO1500-MIB::metro1500PSOn OID value, configure state conditions and alerts, and monitor any ADVA/vendor Metro1500 access multiplexer from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.3 | metro1500 | METRO1500-MIB |
| 1.3.6.1.4.1.2544.1.3.1 | metro1500Main | METRO1500-MIB |
| 1.3.6.1.4.1.2544.1.3.1.3 | metro1500PSTable | METRO1500-MIB |
| 1.3.6.1.4.1.2544.1.3.1.3.1 | metro1500PSEntry | METRO1500-MIB |
| 1.3.6.1.4.1.2544.1.3.1.3.1.2 | metro1500PSOn | METRO1500-MIB |