All MIBs › METRO1500-MIB › metro1500ClockNoFail
metro1500ClockNoFail
Module: METRO1500-MIB
OID (symbolic): METRO1500-MIB::metro1500ClockNoFail
OID (numeric): 1.3.6.1.4.1.2544.1.3.100.0.32
Node type: NOTIFICATION-TYPE
Description: Trap is sent if a Clock is installed and can synchronize with the input Signal. This Trap is not sent if the installed Clock does not have an error Output
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' METRO1500-MIB::metro1500ClockNoFail snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.2544.1.3.100.0.32
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:57034->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (325395146) 37 days, 15:52:31.46 SNMPv2-MIB::snmpTrapOID.0 = OID: METRO1500-MIB::metro1500ClockNoFail
Start monitoring ADVA/vendor Metro1500 access multiplexer with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the METRO1500-MIB::metro1500ClockNoFail OID value, configure state conditions and alerts, and monitor any ADVA/vendor Metro1500 access multiplexer from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.3 | metro1500 | METRO1500-MIB |
| 1.3.6.1.4.1.2544.1.3.100 | metro1500Trap | METRO1500-MIB |
| 1.3.6.1.4.1.2544.1.3.100.0.32 | metro1500ClockNoFail | METRO1500-MIB |