MELLANOX-IF-VPI-MIB :: mellanoxIfVPIPortXmitWait

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › MELLANOX-IF-VPI-MIB › mellanoxIfVPIPortXmitWait

mellanoxIfVPIPortXmitWait

Module: MELLANOX-IF-VPI-MIB

OID (symbolic): MELLANOX-IF-VPI-MIB::mellanoxIfVPIPortXmitWait

OID (numeric): 1.3.6.1.4.1.33049.3.1.1.1.5

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: A VPI counter. The number of ticks during which the port selected by PortSelect had data to transmit but no data was sent during the entire tick either because of insufficient credits or because of lack of arbitration.

What is mellanoxIfVPIPortXmitWait?

Counts ticks during which the port had data queued to transmit but sent nothing, due to insufficient credits or lost arbitration. A rising counter indicates congestion or credit starvation on this InfiniBand link, worth investigating alongside neighboring switch buffer settings.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.33049.3.1.1.1.5
snmpwalk -v2c -c public <target> MELLANOX-IF-VPI-MIB::mellanoxIfVPIPortXmitWait

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.33049.3.1.1.1.5.1
snmpget -v2c -c public <target> MELLANOX-IF-VPI-MIB::mellanoxIfVPIPortXmitWait.1

Start monitoring Mellanox VPI network adapter/switch port (InfiniBand/Ethernet dual-mode) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MELLANOX-IF-VPI-MIB::mellanoxIfVPIPortXmitWait OID value, configure state conditions and alerts, and monitor any Mellanox VPI network adapter/switch port (InfiniBand/Ethernet dual-mode) from a single console.

How to Use in IPNetwork Monitor

Select a Mellanox VPI network adapter/switch port (InfiniBand/Ethernet dual-mode) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type mellanoxIfVPIPortXmitWait into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports a VPI counter. The number of ticks during which the port selected by PortSelect had data to transmit but no data was sent during the entire tick either because of insufficient credits or because of lack of arbitration. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.33049mellanoxMELLANOX-MIB
1.3.6.1.4.1.33049.3mellanoxIfVPIMELLANOX-SMI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.33049.3.1mellanoxIfVPIMibMELLANOX-IF-VPI-MIB
1.3.6.1.4.1.33049.3.1.1mellanoxIfVPITableMELLANOX-IF-VPI-MIB
1.3.6.1.4.1.33049.3.1.1.1mellanoxIfVPIEntryMELLANOX-IF-VPI-MIB
1.3.6.1.4.1.33049.3.1.1.1.5mellanoxIfVPIPortXmitWaitMELLANOX-IF-VPI-MIB