LLDP-EXT-PNO-MIB :: lldpXPnoLocPortStatusRT2

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › LLDP-EXT-PNO-MIB › lldpXPnoLocPortStatusRT2

lldpXPnoLocPortStatusRT2

Module: LLDP-EXT-PNO-MIB

OID (symbolic): LLDP-EXT-PNO-MIB::lldpXPnoLocPortStatusRT2

OID (numeric): 1.0.8802.1.1.2.1.5.3791.1.2.1.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This value represents the status of the corresponding port of the local system according to RT class 2. A value of off(0) means that there isn't any RT2 capability available for this port. When the port is configured for RT2 mode, but the mode isn't active yet the value will be configured(1). If the RT2 mode is configured for this port and the mode is active, the value will be running(2).

What is lldpXPnoLocPortStatusRT2?

Reports this local port's PROFINET RT class 2 real-time status: off(0) if RT2 isn't supported, configured(1) if set up but not yet active, or running(2) if RT2 traffic is actively flowing on the port.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.0.8802.1.1.2.1.5.3791.1.2.1.1.4
snmpwalk -v2c -c public <target> LLDP-EXT-PNO-MIB::lldpXPnoLocPortStatusRT2

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.0.8802.1.1.2.1.5.3791.1.2.1.1.4.1
snmpget -v2c -c public <target> LLDP-EXT-PNO-MIB::lldpXPnoLocPortStatusRT2.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> lldpXPnoLocPortStatusRT2.1

Start monitoring Vendor-neutral PROFIBUS/PROFINET standard (industrial Ethernet switch/field device) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LLDP-EXT-PNO-MIB::lldpXPnoLocPortStatusRT2 OID value, configure state conditions and alerts, and monitor any Vendor-neutral PROFIBUS/PROFINET standard (industrial Ethernet switch/field device) from a single console.

How to Use in IPNetwork Monitor

Select a device implementing LLDP-EXT-PNO-MIB as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type lldpXPnoLocPortStatusRT2 into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This value represents the status of the corresponding port of the local system according to RT class 2. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'running', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.0stdSTART-MIB
1.0.8802iso8802START-MIB
1.0.8802.1ieee802dot1START-MIB
1.0.8802.1.1ieee802dot1mibsSTART-MIB
1.0.8802.1.1.2lldpMIBLLDP-MIB
1.0.8802.1.1.2.1lldpObjectsLLDP-MIB
1.0.8802.1.1.2.1.5lldpExtensionsLLDP-MIB
Numeric OIDNameModule
1.0.8802.1.1.2.1.5.3791lldpXPnoMIBLLDP-EXT-PNO-MIB
1.0.8802.1.1.2.1.5.3791.1lldpXPnoObjectsLLDP-EXT-PNO-MIB
1.0.8802.1.1.2.1.5.3791.1.2lldpXPnoLocalDataLLDP-EXT-PNO-MIB
1.0.8802.1.1.2.1.5.3791.1.2.1lldpXPnoLocTableLLDP-EXT-PNO-MIB
1.0.8802.1.1.2.1.5.3791.1.2.1.1lldpXPnoLocEntryLLDP-EXT-PNO-MIB
1.0.8802.1.1.2.1.5.3791.1.2.1.1.4lldpXPnoLocPortStatusRT2LLDP-EXT-PNO-MIB