LLDP-EXT-PNO-MIB :: lldpXPnoConfigSPDTxEnable

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › LLDP-EXT-PNO-MIB › lldpXPnoConfigSPDTxEnable

lldpXPnoConfigSPDTxEnable

Module: LLDP-EXT-PNO-MIB

OID (symbolic): LLDP-EXT-PNO-MIB::lldpXPnoConfigSPDTxEnable

OID (numeric): 1.0.8802.1.1.2.1.5.3791.1.1.1.1.1

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: The lldpXPnoConfigSPDTxEnable, which is defined as a truth value and configured by the network management, determines whether the PNO organizationally defined signal propagation delay TLV transmission is allowed on a given LLDP transmission capable port. The signal propagation delay is composed of the port transmission delay, the port receiving delay and the line delay. These values can't be transmitted independently of each other. The value of this object must be restored from nonvolatile storage after a re-initialization of the management system.

What is lldpXPnoConfigSPDTxEnable?

Enables (true, the default) or disables transmission of the PROFINET signal propagation delay TLV in this port's outgoing LLDP frames, which bundles the port's transmit delay, receive delay, and line delay together since the MIB notes these can't be sent independently; the setting must survive a management-system restart via non-volatile storage.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.0.8802.1.1.2.1.5.3791.1.1.1.1.1
snmpwalk -v2c -c public <target> LLDP-EXT-PNO-MIB::lldpXPnoConfigSPDTxEnable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.0.8802.1.1.2.1.5.3791.1.1.1.1.1.1
snmpget -v2c -c public <target> LLDP-EXT-PNO-MIB::lldpXPnoConfigSPDTxEnable.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.0.8802.1.1.2.1.5.3791.1.1.1.1.1.1 s <value>

Start monitoring Vendor-neutral PROFIBUS/PROFINET standard (industrial Ethernet switch/field device) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LLDP-EXT-PNO-MIB::lldpXPnoConfigSPDTxEnable OID value, configure state conditions and alerts, and monitor any Vendor-neutral PROFIBUS/PROFINET standard (industrial Ethernet switch/field device) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.0stdSTART-MIB
1.0.8802iso8802START-MIB
1.0.8802.1ieee802dot1START-MIB
1.0.8802.1.1ieee802dot1mibsSTART-MIB
1.0.8802.1.1.2lldpMIBLLDP-MIB
1.0.8802.1.1.2.1lldpObjectsLLDP-MIB
1.0.8802.1.1.2.1.5lldpExtensionsLLDP-MIB
Numeric OIDNameModule
1.0.8802.1.1.2.1.5.3791lldpXPnoMIBLLDP-EXT-PNO-MIB
1.0.8802.1.1.2.1.5.3791.1lldpXPnoObjectsLLDP-EXT-PNO-MIB
1.0.8802.1.1.2.1.5.3791.1.1lldpXPnoConfigLLDP-EXT-PNO-MIB
1.0.8802.1.1.2.1.5.3791.1.1.1lldpXPnoConfigTableLLDP-EXT-PNO-MIB
1.0.8802.1.1.2.1.5.3791.1.1.1.1lldpXPnoConfigEntryLLDP-EXT-PNO-MIB
1.0.8802.1.1.2.1.5.3791.1.1.1.1.1lldpXPnoConfigSPDTxEnableLLDP-EXT-PNO-MIB